3  OVERVIEW 

  DESCRIPTION 

The Motor Output Interface (MOI) 

has an output pair for controlling DC motors which require a reversal of polarity to 

change the direction of their mechanical operation. For example, a DC motor for an electric window mechanism will 

move the window up or down depending on the polarity of the feed to the motor. The MOI also incorporates two standard 

output channels such as is found on the Output Interface. 

Connection to the unit is simple: a large 6 way plug allows 

connections to cables of up to 16 mm2 (6AWG) in size, or multiple smaller conductors. No need for specialized crimp 

terminals and expensive crimp tools to be carried for terminations to CZone, just a blade screwdriver. A protective 

flexible boot offers protection to the connections from harsh environment conditions. 

  FEATURES 

  4 levels of backup fusing including manual override (as required by ABYC) 

  Multiple channels can be bridged together to offer higher current switching 

  Power consumption 12 V: 85 mA (standby 60 mA) 

  Dimensions, WxHxD: 7-29/32"x5"x1-3/4" 200x128x45 mm 

  Small, non metallic, easy to install case 

  2 x 20 amps circuits 

  1 x 20A “H Bridge” output for controlling direction of DC motors through polarity change 

  IPX5 water ingress protection 

  Programmable software fuse sizes 

 

 

Содержание 80-911-0007-00

Страница 1: ...Motor Output Interface MOI User Installation Manual V2 0...

Страница 2: ...cations of either its products or associated documentation Translations In the event that there is a difference between a translation of this manual and the English version the English version should...

Страница 3: ...nance And Repair 5 General Safety and Installation Precautions 5 3 OVERVIEW 6 Description 6 Features 6 MOI Hardware Overview 7 Led indicators 8 4 DESIGN 9 5 INSTALLATION 9 Things You Need 9 Environmen...

Страница 4: ...s chapter 2 of this manual Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and spec...

Страница 5: ...the MOI in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the MOI other than mentioned in point 2 is not considered to be consistent with the inten...

Страница 6: ...cables of up to 16 mm2 6AWG in size or multiple smaller conductors No need for specialized crimp terminals and expensive crimp tools to be carried for terminations to CZone just a blade screwdriver A...

Страница 7: ...tput Circuit Fuses 12 Dipswitch 13 NMEA 2000 Connector 1 DC Power LED 2 Waterproof Cover 3 Circuit ID Labels 4 Protective Boot 5 Channel Status LEDs 6 Network Status LED 7 Module ID Label MOI HARDWARE...

Страница 8: ...dule Not Configured 2 Red Flash Configuration Conflict 3 Red Flash DIP Switch Conflict 4 Red Flash Memory Failure 5 Red Flash No Modules Detected 6 Red Flash Low Run Current 7 Red Flash Over Current 8...

Страница 9: ...f each connected load does not exceed maximum channel rating of 20A Install the appropriately rated fuses for each channel Loads exceeding 20A will require paralleling 2 channels together 5 INSTALLATI...

Страница 10: ...cable grommet for wiring bend radius o Note Cable radius determined by wiring manufacturer 3 Fasten the MOI by using 4 x 8G or 10G 4mm or 5mm self tapping screws or bolts not supplied IMPORTANT The M...

Страница 11: ...utput wires through cable grommet 2 Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten screws to 4 43 in lbs 0 5NM 3 Insert plug firmly i...

Страница 12: ...MAL bottom position of all circuits 3 The ATC fuse should be rated to protect the connected load and the wiring from the MOI to the load and also the ground wire MECHANICAL BYPASS The MOI includes a m...

Страница 13: ...ve advanced functionality such as timers load shedding or one touch Modes of operation a custom configuration needs to be installed Set the dipswitch on the MOI to match the configuration file All oth...

Страница 14: ...e purchased a label sheet WARNING The MOI is only ignition protected with the cover correctly installed INITIAL POWER UP 1 Power up the NMEA2000 Network system will flash all outputs for a short time...

Страница 15: ...SYSTEM DIAGRAM EXAMPLES System Diagram BILGE PUMP BATTERY HATCH LIFTER NMEA 2000 NETWORK DC Negative Input DC Positive Input Reversible output pair CIRCUIT BREAKER Positive DC Output 1 Positive DC Out...

Страница 16: ...0 5 6mm 24AWG 8AWG Output channels 1x 20A H Bridge channel 12 24 2 x 20A Output channels 12 24V Maximum current 60A Total Module Current Dimming Output channels PWM 100Hz Power supply M6 1 4 Positive...

Страница 17: ...ssenger cars and light commercial vehicles with nominal 12 V supply voltage Electrical transient conduction along supply lines only ISO 7637 2 24V Commercial vehicles with nominal 24 V supply voltage...

Страница 18: ...EN CZone Output Interface MOI User Installation Manual 18 8 Declaration of Conformity...

Отзывы: