Auxiliary Digital 
output follows Aux. 
input on Central

Alternate I/O Assignment Setting

:

In the Alternate I/O configuration, the door strike relay on the Remote is activated when the Auxiliary 
digital input signal is triggered on the Central unit.  The Central unit LED input will only trigger the 
LED output on the Remote unit.  This setting can be used when the panel LED output does not 
signify a good badge read.

When the auxiliary digital input on the Central unit is activated (Grounded), the Door Strike Relay on 
the Remote unit will operate.  This is a dual purpose input and also serves as an additional I/O 
channel.  See below.

There is an auxiliary digital output on the Remote unit.  This is a 0 to 5 volt digital output that always 
follows the Auxiliary digital input on the Central unit, regardless of the switch #5 setting.  It can be 
used as an additional low power driver or I/O control. See Auxiliary inputs and outputs for details.

N.C. Contact

Common

N.O.. Contact

Remote Unit

Dip switch #5 is ON

Door Strike relay does NOT follow LED

(Alternate setting) 

LED signal from panel
only activates LED on 
Remote 

Auxiliary Digital I/O Input
triggers Strike Relay

Central Unit

C

R

1 2 3 4 5 6 7 8

Reader LED

Strike Relay Follows
Aux input on Central

Содержание SPX-1200

Страница 1: ...2006 Cypress Computer Systems Inc www cypressworld com Page 1 SPX 1200 Supervised Reader Extender Wiring Diagram and Operators Manual MAN FA SPX 1200 V1 04...

Страница 2: ...al connections Page 9 10 Power connection Page 11 12 13 Communication connections Page 14 Reader data connections Page 15 16 17 Door strike relay Page 18 Alternate I O Function Dip Switch 5 Page 19 20...

Страница 3: ...Aux Output 3 Line Line RS 232RX RS 232 TX Gnd Aux Input 1 Suprex 1200 Central Unit 8 24VDC Gnd 5Vdc J1 J2 J3 Alarm Output Line Line Rly N C Rly Com Rly N O RS 232RX RS 232 TX Gnd LED IN Aux Output 2...

Страница 4: ...alling Edge Reserved F2F x ON DIP Switch Settings Quick Reference CYPRESS SUPREX SPX 1200 Dip switch 4 is ON Disable Pullup resistors Dip switch 4 is OFF Enable Pullup resistors 1 2 3 4 5 6 7 8 NOT US...

Страница 5: ...eader and door gate hardware The reader data and status signals are sent over a single pair of wires up to 10 000 feet An RS 232 connection can also be used The SPX 1200 series has the ability to be f...

Страница 6: ...configuration can be verified and any potential problems can be solved much easier than if the units are separated by several thousand feet We recommend that the installation proceed in the following...

Страница 7: ...ss Suprex supports multiple reader data formats Each data format can be set with the dipswitch The dip switch format will be read each time the unit powers up Mode 0 Wiegand mode Supports Wiegand data...

Страница 8: ...O points and Power and Communications The Central and Remote are physically alike and will be identified by a sticker or permanent label with a large C or Central label and a large R or Remote label C...

Страница 9: ...l Identification Central unit RS 232 RX Ground Data 0 Clock F2F Data 1 Data LED Panel Port Signals 8 24 VDC Ground 5 VDC Alarm Relay N O Alarm Relay Com Alarm Relay N C Aux Digital I O 1 Output Aux Di...

Страница 10: ...Terminal Identification Remote unit RS 232 RX Ground Data 0 Clock F2F Data 1 Data LED Reader Signals 8 24 VDC Ground 5 VDC Alarm Relay N O Alarm Relay Com Alarm Relay N C Aux Digital I O 3 Output Aux...

Страница 11: ...ntral and Remote units It requires 4 wires to connect the two units together A typical power supply would be a 12Vdc wall wart rated at 500 ma The power supply can be located at either the Central or...

Страница 12: ...is method uses two power supplies One to power the Central and the other to power the Remote unit It requires 2 wires to connect the two units together The power supplies are located at both the Centr...

Страница 13: ...ower both units The power supplies are located at both the Central and Remote unit The 5 volt power must be connected to the reader interface 5 Volt and Ground connections The other unit can be suppli...

Страница 14: ...the units connected using A B or C power connections turn on the power supply Only power and communications connections should be made at this point Data and I O connections should be made after powe...

Страница 15: ...ader Central Unit Remote Unit The SPX 1200 has eliminated the need for Pullup resistors in most installations Dipswitch 4 controls whether the internal pullup resistors are turned on or not Dipswitch...

Страница 16: ...ss Computer Systems Inc www cypressworld com Page 16 Detailed Reader Port Connections Central unit Power supply connections are not shown for clarity Ground Data 0 Clock F2F Data 1 Data LED Panel Port...

Страница 17: ...Detailed Reader Port Connections Remote unit Power supply connections not shown to clarify data connections Data 0 Clock F2F Data 1 Data LED Ground 5 VDC R Reader Interface 5 Vdc Reader Data 0 Clock F...

Страница 18: ...nd 0 volt reference it will trigger the LED output and Strike relay on the Remote unit The dip switch on the Central unit can set a different mode for triggering the Door Strike 1 2 3 4 5 6 7 8 N C Co...

Страница 19: ...the Door Strike Relay on the Remote unit will operate This is a dual purpose input and also serves as an additional I O channel See below There is an auxiliary digital output on the Remote unit This i...

Страница 20: ...and Digital output 1 on the Central unit The Alarm signal will be output on Digital Output 1 and the Digital Output 1 signal will be output using the Relay on the Central unit Note Loss of communicati...

Страница 21: ...atus of its associated input A signal change on Input 1 will be seen on Output 1 input 2 on output 2 input 3 on output 3 The Alarm Output is activated when there is a loss of communication between the...

Страница 22: ...AC Suprex 1200 Remote Unit J1 J2 J3 Aux Output 3 Aux Input 1 Suprex 1200 Central Unit J1 J2 J3 Alarm Output Rly N C Rly Com Rly N O Aux Output 2 Aux Input 3 R C Rly N C Rly Com Rly N O Door Strike Aux...

Страница 23: ...han 5 Volts can damage the board The digital inputs are pulled up to 5 Volts and operate as active low they will operate when connected to ground 0 Volts They can be driven by a digital output from a...

Страница 24: ...ment utilizing 5 Volt logic level signals such as panels and gate controllers Check the manufacturers specifications for the equipment that you will interface to the Suprex to verify signal levels Oth...

Отзывы: