Document Number: 002-00886 Rev. *B
S29GL01GP
S29GL512P
S29GL256P
S29GL128P
11.2
Operating Ranges
Notes
1. Operating ranges define those limits between which the functionality of the device is guaranteed.
2. See also
Ordering Information on page 4
3. For valid V
CC
/V
IO
range combinations, see
Ordering Information on page 4
. The I/Os do not operate at 3 V when V
IO
= 1.8 V.
11.3
Test Conditions
Figure 11.3
Test Setup
Note
If V
IO
< V
CC
, the reference level is 0.5 V
IO
.
Specifications
Range
Ambient Temperature (TA), Industrial (I) Device
–40°C to +85°C
Ambient Temperature (TA), Commercial (C) Device
0°C to +85°C
Supply Voltages
V
CC
+2.7 V to 3.6 V or
+3.0 V to 3.6 V
V
IO
Supply Voltages
V
IO
+1.65 V to V
CC
Test Specifications
Test Condition
All Speeds
Unit
Output Load Capacitance, C
L
(including jig capacitance)
30
pF
Input Rise and Fall Times
5
ns
Input Pulse Levels
0.0–V
IO
V
Input timing measurement reference levels (See Note)
0.5V
IO
V
Output timing measurement reference levels
0.5 V
IO
V
C
L
Device
Under
Test