CY3274 Cypress High Voltage Programmable PLC Development Kit Guide, Doc. # 001-53598 Rev. *G
55
Code Examples
10
Transmit Source Address
Type
TX_Config
Logical Address
(default)
provides option to choose
between logical or physical
address for transmitter source
11
Transmit Destination
Address Type
TX_Config
Logical Address
(default)
Provides option to choose
between logical or physical
address as transmitter
destination address type
12 Transmit Service Type
TX_Config
Acknowledgement
Mode
Transmissions are
acknowledged
13 Transmit Retry Count
TX_Config
3
Number of times a transmitter
should retry before sending a
new packet
14 Transmit Payload Length TX_Message_Length 0
Length of the payload
15 Receive Enable
PLC_Mode
Enable
Enable Receiver Mode
16 Noise Threshold Value
Threshold_Noise
87 dBuV (default)
Threshold for BIU detection
(set to 87 dBuV for CENELEC)
17 Band In Use
PLC_Mode
Enable (default)
Allows option to only send data
when no other node is using
the powerline for its
communication
18 BIU Time Interval (min)
Timing_Config
85 ms (default)
Set BIU Time interval
19 BIU Time Interval (span)
Timing_Config
30 ms (default)
Set time interval span
20 BIU Timeout
Timing_Config
1.1 s Timeout
(default)
Set BIU Timeout value
21 BIU Timeout Interrupt
INT_Enable
Enable (default)
Enable Interrupt for BIU
Timeout and the Modem is
unable to Transmit, if Disable
BIU = 0
22 ACK Timeout
Timing_Config
Auto +20 ms
Time for which Transmitter
waits for ACK after Auto set
time.
23 Lock Configuration
PLC_Mode
Unlock (default)
Allow device to be configured
remotely
24 Rx Overwrite
PLC_Mode
Disable (default)
If RX Buffer is full, new RX
Message is dropped.
25
Destination Address
Verification
PLC_Mode
Do not Ignore
Check if the Destination
Address is a match before
processing the packet
26 CRC Address Verification PLC_Mode
Do not Ignore
Drop the packet if CRC fails
27 Addressing Mode
PLC_Mode
8 bit
Select between 8 bit and 16 bit
Table 5-1. PLT UM Configuration
(continued)
No.
Property
Register
Value
Details
Содержание CY3274
Страница 74: ...74 CY3274 Cypress High Voltage Programmable PLC Development Kit Guide Doc 001 53598 Rev G A 2 2 Ground Layer ...
Страница 75: ...CY3274 Cypress High Voltage Programmable PLC Development Kit Guide Doc 001 53598 Rev G 75 A 2 3 Power Layer ...
Страница 76: ...76 CY3274 Cypress High Voltage Programmable PLC Development Kit Guide Doc 001 53598 Rev G A 2 4 Bottom Layer ...
Страница 77: ...CY3274 Cypress High Voltage Programmable PLC Development Kit Guide Doc 001 53598 Rev G 77 A 2 5 Top Silkscreen ...