~2~
1. introduction ................................................................................................................................................ 2
1.
I
NTRODUCTION
Before installing the device, read the following operating instructions. Installation may only be carried out by a
qualified person with the adequate qualifications.
This manual applies to the PC-4000 digital panel which is part of the CC4000 system. The description of
programming and setting up with the rest of the system elements can be found in the
CC4000 System Manual.
Panel PC-4000 and devices connected to it are only allowed to be supplied with very low voltage (ELV) with a value
not exceeding the acceptable safe touch voltage. Power devices (12V DC power supplies)
must
comply with EMC
standards and safety in accordance with applicable European Union standards and ensure full
galvanic
isolation from the power grid.
The device is equipped with a 2.5 A fine fuse It is forbidden to connect foreign installations and devices to the
terminals of the PC-4000 board, as this may result in unforeseen operation of the device, fire or electric shock.
Terminal marking on the PC-4000 board:
MAIN CONNECTOR:
+12V
Positive power supply
GND
Supply earth voltage
SERB
Communication series B
SERA
Communication series A
SPK
Audio speaker signal
MIC
Audio sound microphone
CONNECTOR OF ELECTRIC STRIKES:
GND
Electric strikes ground
LOCK1
Main electric strike
LOCK2
Additional electric strike
GND
Additional button ground
WZ
Additional button