~6~
It should be noted that the main connector and the connector of the electric strikes are of the detachable
type. Below is the figure with the connector inserted and removed. The connectors are inserted by
pressing-in.
5.
P
ROGRAMMING
A complete description of the programming procedure can be found in the manual for the CC4000 system, but the
functions related to the PC-4000 panel itself will be described below.
Each panel is protected by a password which is factory set to 123456. To start the programming procedure, enter
the following on the enabled panel in standby mode: *01*, then 6-digit panel serial number, confirm with '*' and enter
the password, and confirm with '*'. So, for example, for the panel of serial no. 150000 and password 123456, enter
the sequence *01*150000*123456*.
All P01 program sub-programmes relate to the panel memory, such as configurations of electric strikes, pairing with
the control panel (SLAVE panel), changing the password, number range, service key fobs and sub-program 10 for
reading the supply voltage, lighting and CPU temperature.
The LOGO consists of four sequences of 8 characters changed every 2 seconds. Its change is possible only from
the programmer. Reset to factory settings of the panel does not change the LOGO!
Below are examples of settings programmed using the GC-2000 programmer