Off-Grid Output (AC)
Nominal power
240W/300VA
Nominal voltage
230Vac, single phase
Nominal frequency
50/60Hz (default is 50Hz)
Overload capacity
105-125%, 1 minute
125-150%, 30 seconds
>150%, immediately
Regulation
Safety
IEC 62109-1/-2
IEC62040-1
EMC
IEC 61000-6-1
IEC 61000-6-3
General
Indicator
PV/Battery/On-Grid/Off-Grid LEDs
Button
One button for ON, off, and select functions
Operation temperature range
-10-50
℃
(de-rating above 40
℃
)
Storage temperature
-20-40
℃
Relative humidity
0-95%
Operating elevation
0-2000m (0-6666ft)
Cooling
Natural convection
Mechanical
Dimension (W*H*D, mm)
292*186*202
Weight
9kg
Package dimension
(W*H*D, mm)
380*305*290
10.2 Torque Values
Table 10-2 Torque values
Battery cover screws
10kgf.cm (0.98N.m)