10
Specification
10.1 Specification of CPSHB300ETR
Table 10-1 Specification
CPSHB300ETR
PV Input
Max. input power
310W
Absolute max. input voltage
50Vdc
Full power voltage range
34-38Vdc
Operating voltage range
28-48Vdc
Rated input voltage
36Vdc
Max. input current
9Adc
MPP Tracker
1
Measurements deviation
Voltage: <2%
Current: <2%
Power: <3%
Battery Input (internal)
Battery type
VRLA rechargeable battery
Operating voltage range
20-28.8Vdc
Nominal voltage
24Vdc (12Vdc*2)
Nominal Capacity
9Ah
Shutdown voltage
20V for >100W
21V for 30-100W
22V for <30W
Measurements deviation
Voltage: <2%
Current: <2%
Power: <3%
USB Charger
Nominal charge power
10W
Nominal voltage
5Vdc
Number of USB port
2
Max. charge current
2A/2A (per port/total)
Grid (AC)
Nominal voltage
230Vac, single phase
Frequency range
50/60Hz
±
0.3Hz
Voltage range
-10%/+10%
Max. current bypass to load
3A