Orange
Orange
Orange
7A
Orange
Orange
Orange
9A
Procedure for confirming charge current setting and exiting setting mode,
When the charge current setting is changed to what user wants.
Press and hold the button
3s later,
inverter confirms the setting and exit setting mode, jump to Sleep mode and all LEDs off.
When all LEDs
are Green, release the button immediately.
Inverter goes back to normal operation.
6.4 LEDs Indicators
Inverter has 4 LEDs. They are: PV, Battery, On Grid, and Off Grid.
The LEDs would display Green, Red, or Orange to indicate Status or Operation modes.
Table 6-2 LEDs indicators for On-Grid (Self-consumption or Bypass) operation
Flash frequency (on/off):
: 2s/1s;
: 0.5s/0.5s;
: 0.2s/0.2s
Status
PV Panel
Battery
AC/On-Grid
Off-Grid
Explanation
Countdown
Green
Depend on
the status of
charge, refer
to next row
Green Flash
Off
Countdown and prepare to
On-Grid operation
Normally
operating
Green
Green
Green
Off
Operating normally with
battery capacity
≧
75%
Green with
slowly
flashing
Operating normally with
battery capacity between 50%
and 75% and under charging
Orange with
slowly
flashing
Operating normally with
battery capacity between 25%
and 50% and under
charging<24.5Vdc and
≧
23Vdc and charging
User Manual
16 Hybrid CPSHB300ETR
Содержание CPSHB300ETR
Страница 1: ...User s Manual CPSHB300ETR Cyber Power Systems Inc www cyberpower com...
Страница 2: ......
Страница 18: ...Fig 5 4 Location of extended battery connector User Manual 12 Hybrid CPSHB300ETR...
Страница 33: ...Note...
Страница 34: ...Note...
Страница 35: ......
Страница 36: ...www CyberPower com K01 0000591 00...