Installing the VoIP Emergency Intercom
Parts List
Operations Guide
930279M
CyberData Corporation
8
2.2 Intercom Setup
2.2.1 VoIP Intercom Connections
Figure 2-5
shows the pin connections on the J7 (terminal block). This terminal block can accept a
wire range from 16 AWG to 26 AWG.
Note
As an alternative to using PoE power, you can supply 5 VDC at 1000 mA into the terminal
block.
Figure 2-5. VoIP Intercom Connections
Alternate Power Input:
1 = +5V at 1000 mA
2 = Power Ground
Relay Contact:
(2A at 30 VDC for Continuous Loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
J3 - Terminal Block
3
4
12 3
4 5
6
Accept Wire Range
up to 16 Gauge