Operating instructions Multi-cell compressor RKL 160
Malfunctions
26
8.3 Malfunction table
Malfunction:
Possible cause
Corrective action
Execution
Delivery rate too
low
Air filter soiled
Clean or replace filter cartridge
Operator
Pressure line leaky
Eliminate leakage
Specialised
staff
Speed too low
Correct speed (refer to Tab. 2)
Operator
Abnormal noise
emission
RKL 160 is badly aligned
Align the RKL 160 precisely.
Specialised
staff
Bearing defective
Replace bearing
Manufacturer
Rotor vanes generate knocking
noise due to excessive wear.
Replace rotor vane
Specialised
staff
Wrong speed
Maintain speed range
Operator
Foreign bodies in the RKL 160
Remove foreign matter. Flush out
the RKL 160.
Specialised
staff
Final pressure too high
Adhere to permissible final
pressure
(refer to Tab. 2)
Operator
Compressed air
temperature too
high
Head loss in suction system too
high
Clean or replace filter cartridge
Operator
Final pressure too high
Adhere to maximum final pressure
(refer to Tab. 2)
Check pressure line for clogging
Specialised
staff
Wrong speed
Maintain speed range
Operator
Pressure gauge defective
Replace pressure gauge
Specialised
staff
Suction filter contaminated
Clean filter element
Operator
Operating
pressure is not
attained
Wrong speed
Maintain speed range
Operator
Pressure gauge defective
Replace pressure gauge
Specialised
staff
Leakage in the pressure line
Eliminate leakage
Specialised
staff
Power requirement
too high
End pressure too high
Adhere to permissible final
pressure
(refer to Tab. 2)
Operator
Shut-off valve not fully open
Fully open shut-off valve
Operator
Speed too high
Correct speed (refer to Tab. 2)
Operator
Pressure gauge indicates
incorrectly
Replace pressure gauge
Specialised
staff
Safety valve blows
off
Closed valves in the pressure
line
Open valves
Operator
Pressure line clogged
Eliminate clogging
Operator
Tab. 5: Malfunction table