Operating instructions Multi-cell compressor RKL 160
Design and function
18
4.2 Cooling
The RKL 160 is air-cooled. Ensure at installation that no heat
accumulation results and that the cooling air can circulate freely.
The front cooling air entry openings must not be covered.
Fig. 2: Cooling air guide
1
Cooling air entry
2
Cooling air exit
4.3 Function
Functional principle
In the working area, self-lubricating sliders in conjunction with the
impeller and the casing form cells that are separated from each
other and steadily grow (sucking) or shrink (compressing) with
each revolution.
Lubrication
Lubrication of the rotor bearing is warranted by a permanent
grease fill.
Cooling
Heat removal is performed by casing ribs on the entire casing
surface with targeted cooling air guidance, via a ventilation wheels.