35
4.15 Fascias
The design of these affects combustion, therefore only the correct fascia supplied with
the appliance may be fitted.
4.16 Fire Guards
The user or other persons in the room in which the appliance is fitted shall be
protected as far as is reasonably possible from the risk of burns or ignition of their
clothing from the heat, from the flames and incandescent parts of the appliance by
either:
a) Installing a fireguard which conforms to BS 7977-1: 2002,
6.4.8;
or
b) A tactile separator in the form of either
i)
A hearth provided in accordance with
11.3.2
, or
ii)
A fender, kerb, horizontal bar, or other barrier, being fixed not less than 50
mm above floor level and not more than 1000 mm above floor level, and
positioned at least 300 mm in front of and 150 mm beyond the edge of
any naked flame or incandescent part of the fire-bed.
It is recommended that a fireguard conforming to the requirements of BS 7977-1:
2002,
6.4.8
be fitted if the fire is used in the presence of young children, the elderly or
the infirm.
The installer is to advise the user not to stand too close to the appliance for
prolonged periods of time and warn that loose clothing is particularly at risk of burning
due to the presence of an unguarded flame.
In addition, the installer is to advise the user against placing combustible materials
directly in front of the appliance. Floor coverings, such as carpets, are considered to
be acceptable.
4.17 Working surfaces
In normal use all surfaces of the appliance get hot [especially the fascia area above
the heat deflector], so can be considered to be working surfaces and therefore
should not be touched.
ONLY USE GENUINE REPLACEMENT PARTS.
The following information supplied in this manual is correct at the time of publish;
Dated on the 05/06/07. There may be changes made in future as we improve our
products. If there are any queries please write or call our technical department.
CVO Fire Ltd, CVO House, 4 Beaumont Square
Aycliffe Industrial Park, Newton Aycliffe
County Durham, DL5 6SW
T – 01325 327 221
F – 01325 327 292
Email – [email protected]
Содержание Flueless Fire Pod
Страница 5: ...5 4 2 Parts List...
Страница 6: ...6 4 3 Overall Dimensions Dimensions of Fire Unit with Metal Fascia...
Страница 7: ...7 Dimensions of Fire Unit with Stone Fascia...
Страница 15: ...15 The Remote Controls Black Box left Controls Valve Right...
Страница 18: ...18 Pod Gas Inlet electric supply and hardwire switch cable areas...
Страница 22: ...22 4 7 Remote Wiring Diagram...