This appliance is very efficient. The burner system is very clean burning; an oxygen
depletion sensor will sense any significant oxygen depletion in the room and shut the fire
down safely.
4.4 Appliance Data
Refer to the appliance data (affixed behind the facia). ENSURE THAT THE LOCAL
CONDITIONS OF USE CORRESPOND TO THE DATA ON THE BADGE.
Natural
Gas
Gas Category
I
2H
Gas Type
G20
Supply Pressure
(mbar)
20
Countries of
Destination
AT, CH, CZ, DK, ES, FI, GB, GR, IE, IT,
PT, SE
Heat Input (Gross, kW)
High 2.4
Low 1.4
Inlet Connection
8mm Compression
Injector
Elbow 0.4mm (multiholed) Stereomatic
Pilot P4-27
*The inlet pressure must be / - 1mbar specified, with
all
gas
appliances in the
house switched on and also with just the Fire Pod operating. If outside of this tolerance
the fault is most likely to be in the installation pipe work or service governor at the meter.
If the problem is the meter governor, this is the property of the gas service provider (such
as Transco or Bord Gais) and they should be called to rectify this.