Symptom Check
List
Tick
Check Remote is working properly
Check power supply.
Check fuses.
Unit does not respond.
Check wiring is correct
Check Battery Power.
Remote does not work.
Check Remote eye is visible and facing in the correct position.
Check Switch is wired properly.
Hardwire switch does
not work.
Check Hardwire switch’s Green Block is wired correctly.
Check spark lead is connected properly.
Unit clicks but no spark
or weak spark.
Check spark electrode is in the correct area and the gap correctly
distanced.
Check for a good spark.
Check the spark is in the right area.
Check if the ventilation is not too strong.
Unit sparks but does not
light pilot.
Check if there is gas running through.
Check isolation tap/shut off valves are free from grease.
Check isolation tap/shut off valve are on.
If there is no gas.
Check for blockages
Check pressure is correct.
Check for blockages.
Check for draughts.
If there is gas but pilot
does not light
Check the pilot gas slot is clear.
Check the pilot flame is heating the thermocouple.
Check the thermocouple nut is properly tightened into the valve/interrupter
block.
Check that the pilot lights early on ignition clicks.
Pilot lights but does not
light main burner
Check ventilation is not too strong.
Check thermocouple nut is properly secured to the interrupter block on the
valve.
Check ventilation is not too strong and the flame is not blowing off the
thermocouple.
Burner lights but turns
off after a few minutes
Check gas pressure is correct.
Содержание Flueless Fire Pod
Страница 5: ...5 4 2 Parts List...
Страница 6: ...6 4 3 Overall Dimensions Dimensions of Fire Unit with Metal Fascia...
Страница 7: ...7 Dimensions of Fire Unit with Stone Fascia...
Страница 15: ...15 The Remote Controls Black Box left Controls Valve Right...
Страница 18: ...18 Pod Gas Inlet electric supply and hardwire switch cable areas...
Страница 22: ...22 4 7 Remote Wiring Diagram...