Page 31 of 34
Oxygen Depletion Pilot System
There is a highly sensitive oxygen depletion sensor designed into the pilot
light. If any part is damaged the entire unit must be replaced. Do not
attempt to bend or alter the flame head, thermocouple or aeration hole. Use
only genuine spare parts as similar looking parts from other appliances may
well give different or inferior performance and could lead to a hazard.
Spark Failure
The gap between the pilot electrode and the pilot should be 3.5 – 4.5mm
and normally adjustment is not necessary (the electrode is very brittle). The
spark should jump across the gap between the electrode and the gas outlet
on the pilot head. If the ignitor fails, a lighted taper can be inserted into the
pilot area to check that gas is reaching the pilot.
Decorating:
Never use this appliance when decorating. Allow a number of days after
decorating for the fumes to disperse before using this appliance. Using this
appliance during or after decorating can cause fumes to enter the room.
Cleaning instructions:
The fascia should be cleaned with warm soapy water; a suitable metal polish
should only be used for the stainless steel parts. Care should be taken
when polishing the vanity cover. It is very important that no polish should
be used on the surface of the burner. No residue of polish should be left as
this may cause unpleasant odours and could lead to staining within the
burner opening when the appliance is used.
New Fire Smell / Burn in Period
On initial light up of a new appliance, the ‘newness’ will burn off within the
first few hours of operation. During this period some smoke may be emitted
from the outlet grill, this should be no cause for concern. Accordingly, the
room should be well ventilated with all windows and doors open during this
period.
Depending on your use, the burn-in period may take a few hours or a few
days. Also if you have a sensitive sense of smell you may notice slight
odours during operating after the burn-in period is over. Keep your house
well ventilated during the burn-in period. The odour and haze emitted during
the burn-in period can be quite noticeable.
Содержание FIRE LINE FLUELESS