Page 13 of 34
Warning for Fire Guards and Hearths
The appliance is not installed with an integral guard. In normal use
consideration may be given to the use of a fireguard conforming to BS6539
or BS6778, so that the approach to the appliance is limited such that access
to the flame is minimised. It is recommended that a fireguard conforming to
the requirements of BS6539 or BS6778 be installed if the appliance is used
in the presence of young children, the elderly or the infirm. For some
countries a non-combustible hearth must be installed in front of the
appliance in accordance with national regulations (e.g. United Kingdom). In
addition, the installer is to advise the user against placing combustible
material directly in front of the appliance.
Clearance to Combustible Materials and Shelves
A non-combustible shelf may be fitted to within 1500mm of the top edge of
the outlet of the fire. Note that shelves will get hot and delicate ornaments;
e.g. wax candles etc. should be kept away from hot surfaces.
As with all flueless fires the possibility of convection staining on surfaces in
the vicinity above the fire outlet shall be considered and the user advised.
Particular attention should be taken to ensure soft furnishings such as
scatter cushions, rugs and curtains are kept at least 1.5 metres from the
appliance. Material of any description should not be thrown on to the fuel
bed.
Preparing the Appliance for Installation
Unpack the unit. Ensure the appliance is correctly marked for the gas it is to
be used with. Take the fascia panel and stand this against a flat surface – Do
not lay the fascia flat.
DO NOT ATTEMPT TO USE THE APPLIANCE IF ANY PART OF THE
APPLIANCE IS FOUND TO BE DAMAGED.
Decide upon a route for the gas supply and if this is to be a concealed supply
it needs to be
located to the bottom right
of
the fire. Lay in the supply as
required. Where pipes pass through a wall, cavity or un-vented void there
should be no joins in this area and the pipes should be fully sleeved. Before
pushing gas pipes through walls seal the pipe ends to prevent debris
entering the pipes.
The instructions for installation and maintenance and the user instructions
shall be handed to the user. The installer shall instruct the user in the safe
use and regular maintenance of the appliance and advise that the ventilation
opening shall not be blocked or restricted in any way.