Page 29 of 34
Appliance Start Up / Shut Down Instructions
The manual switch is located on the right side behind the fascia. The
positions of the control valve are depicted on the control panel fitted
around the control knob.
If the main burner or pilot lights are extinguished for any reason, do not
attempt to relight the pilot within 3 minutes.
The OFF position is self-explanatory - preventing any gas from passing
through the control valve to either the pilot burner or to the main
burner.
By pressing the control knob in, it is possible to turn it anti clockwise.
The first function is to turn on the gas to the pilot - this occurs just before
reaching the PILOT position. If the fire has not been lit for some time it may
be necessary to hold the knob in this position for some seconds to clear the
air from the pipe and allow gas to reach the pilot burner.
Once gas is available at the pilot, continued rotation (anti-clockwise) will
cause the piezo igniter to spark. This is accompanied by a click at the valve
and should result in the pilot burner igniting. This can be verified by looking
at the front central area of the burner unit. Once the pilot is lit, the control
knob should be pressed in and held for 10-12 seconds. In this time the pilot
flame will have heated the flame supervision thermocouple sufficiently to
operate a hold-on magnet within the valve. The knob should then be turned
so that the pointer is approximately horizontal. This allows gas at a low rate
to enter the burner and be ignited by the pilot flame. Once ignition has
taken place, the fire may be set to any level between MAX and MIN by
rotating the control knob accordingly. [See Image above]