Fault Diagnosis
All CVO Fires are given a full function test at the factory including
being run for a number of minutes to ensure there are no faults. It is
highly unlikely that if the unit has been installed correctly as set out
in the manual that the fire will not function. The cause is normally
due to an installation fault.
Symptom Check
List Tick
Check for a good spark
Check the spark is in the right area
Check the ventilation is not too strong
Unit sparks but
does not light
pilot
Check there is gas running through
Check isolation tap/shut off valves are free from grease
Check isolation tap/shut off valves are on
There is no gas
Check for blockages
Check inlet gas pressure is correct
Check for blockages in pipe work
Is there another gas appliance in the house which is causing a
pressure drop?
Check for strong draughts
There is gas
but pilot does
not light
Check the pilot gas slot is clear
Check the pilot flame is heating the thermocouple
Check the thermocouple nut is properly tightened to the valve
Is there another gas appliance in the house which is causing a
drop in gas pressure?
Pilot lights but
does not light
main burner
Check Room Size and Free Air Vent Comply to CE approval as
shown in Technical Data
Check thermocouple nut is properly secured to the valve
Check that drafts are causing the pilot flame to blow off the
thermocouple
Burner lights
but turns off
after a few
minutes
Is the gas pressure correct? Is there another gas appliance in
the house which is causing the gas pressure to drop?
Check “Free Air” Wall Vent is not blocked.
Check “Free Air” Wall Vent Size complies with Approval
Check “Room Size” complies with CE Approval
Noisy Pilot /
Appliance Shut
Down
Check Gas Pressure complies with CE Approval