Installation
Connect the Power Cord to the Brewer (Brewers With a
Strain Relief Mounted to the Back)
1 Place the water tower on a sturdy surface. Remove the
top and side covers.
2 If the brewer will be operating using 120 Vac, locate the
jumper on the terminal block inside the water tower and
remove the cap, then connect the end of the jumper wire
to the L2 terminal on the terminal block.
3 Loosen the strain relief on the back of the brewer.
4 Feed the end of the power cord into the strain relief.
5 Connect the wires on the power cable to the terminal
block inside the brewer.
6 Tighten the strain relief. Leave the covers off until all the
water tower connections are made, later in the installation
process.
Prepare the Countertop
7 Holes must be cut into the counter top prior to installing
the brewer. The hole pattern is critical for proper
operation. See
Figure 3
on the following page. The two
CSFXIFBETNVTUmUXJUIJOBGPPUCZGPPUBSFB
Packed with the unit is a full-size template (Part # WC-
390245). Use the template for cutting the required holes
needed for installing the brew heads, touchscreen and
drip tray. The two largest circular holes are for the brew
head assemblies, along with three stud holes for the
mounting plate for each head. Also, there is a circular
hole for the touch screen, along with the two mounting
holes. The drip tray can be inset into the counter or
NPVOUFEnVTI*OTFUJOTUBMMBUJPOJTSFDPNNFOEFE5IF
rectangular hole shown in
Figure 3
is for inset installation.
*GUIFESJQUSBZXJMMCFNPVOUFEnVTIBDJSDVMBSIPMFJT
drilled in the location shown for the drain instead of a
rectangular hole.
Consideration must be made for the drip tray drain
system. The drip tray comes with a 1/2” NPT X 3” nipple
and a 1/2” NPT barbed elbow. Either may be used to
connect the drain system (supplied by the purchaser) to
the bottom of the drip tray. See
Figure 4
for dimensions.
INSTALLATION INSTRUCTIONS
II12
SERA2, INSTALLATION INSTRUCTIONS
040220C
Figure 2 - Parts of the Brewing System
(Front View)
Water
tower
Right
brew
head
Countertop
UCM/
touch-
screen
Left
brew
head
WARNING:
Make sure that power to the water tower remains disconnected until installation is complete.
If the water tower will be connected to a junction box, turned off power at the circuit breaker panel and
lock out and tag the circuit breaker.
Figure 1 - Power Cord Connection
Strain
relief
Terminal
block