FLUSHING SYSTEM
The system must be flushed after each use to protect the equipment from the corrosive
materials in the formulation.
CAUTION
Never handle any parts that come in contact with formulation until the unit has
been thoroughly flush with isopropyl alcohol or other recommended flushing
agent.
TO FLUSH THE SYSTEM:
1.
With the engine and blower operating, place the momentary toggle switch on the
remote control box in to the “FLUSH” position (hold it in to the Flush position).
2.
Place “SPRAY” toggle switch on the remote control box in to the “ON” position.
3.
Flush for 3 to 5 minutes.
4.
Place “SPRAY” toggle switch on remote control box in to the “OFF” position.
5.
Release the momentary toggle switch on the remote control box from the
“FLUSH” position.
FLUSH OPERATION SEQUENCE WITH
REMOTE CONTROL BOX
1).
Hold the
“Chemical/Flush”
toggle switch in the
flush
position
2).
Move the “Spray”
switch to “On”.
3).
After about 3
minutes move the
“Spray” switch to
“Off”, then release
flush switch.