11.
Adjust the knob for the rate of flow specified by the formulation label that pertains
to your vehicle speed.
Example:
If a formulation label calls for an output of 3 oz at 5 MPH (89 ml at 8
Km/h), 6 oz at 10 MPH (177 ml at 16 Km/h), 9 oz at 15 MPH (266 ml at
24KM/h), and 12 oz at 20 MPH (335 ml at 32 Km/h), you may set the flow
rate at any of these speeds. If the vehicle is moving at 10 MPH (16 Km/h),
set the rate knob to dispense 6 oz (177 ml), which will appear on the
digital readout window. Once the rate of 6 oz (177 ml) is established at 10
MPH, leave the rate knob into that position. From this point on, when the
vehicle speed increases the output will automatically vary proportionately.
12. At this point the OUTPUT light should also be ON. If the range is adjusted beyond
the limits of the measuring system, the FAULT light will come ON.
13. The Spray output can now be started and stopped by placing the OUTPUT switch
in the ON or OFF position as required.
NOTE
If the vehicle is driven over 22 MPH (35 Km/h), the fault light will come ON. If the vehicle
is driven below 5 MPH (8Km/h), the spray will automatically shut off.
FINISHED OPERATION
When the spraying operation is complete, the unit must be flushed in accordance with
FLUSHING SYSTEM section of this manual
.