Part No. 4801-5120 Rev. 1-2020
Mega-Cool System
Page 14 of 48
End Cap Assembly
NOTE: End cap assembly shown above-right glues onto the pump
side of the reservoir.
End cap for connecting
reservoir to pump supply
line.
NOTE
: Holes must be
pointed downward.
Rubber
Gasket
1028-5003
1½” Tank
Head
Adpt. Fitting
1021-6021
1 ½” Tank
Body
Adpt. Fitting
1021-6020
PVC Cap 1-
1/2”
1021-6017
Pick-Up Pipe
1-
1/2” x 2’
0406-5007
IMPORTANT!
Be sure to glue end cap
onto end of suction pipe!
This will affect the way
pump will prime
!
End
Cap
Install PVC End Caps
1. Glue 1 ½
"
end cap of Pick-Up Pipe onto end of pipe as
shown in diagram above left. Rotate Pick-Up Pipe to orient
holes facing downward. Glue Pick-Up Pipe into pipe
adapter fitting on inside of end cap as shown above.
NOTE
: If a Center-Mount In-Line Pump System is being
installed, the Pick-Up Pipe should be installed as shown
above.
2. Glue PVC end cap assembly into 'In-Line Pump side' of
reservoir.
IMPORTANT! Before gluing, rotate PVC end cap
assembly to place Pick-Up Pipe at bottom of reservoir.