Part No. 4801-5120 Rev. 1-2020
Mega-Cool System
Page 32 of 48
Flush System
– In-Line Pump (In-Line Center Mount Systems 10 ft. to 120 ft.)
It is very important to flush the system. After completing system assembly, follow steps below in order to flush out debris from pipes.
1. Open ball valves at both ends of system. See diagram above.
2. Turn on water. Fill reservoir to fill line. Fill the Strainer Basket.
WARNING
: Do not over-tighten the Strainer Basket lid. Hand-tight ONLY.
3. Turn on In-Line Pump to flush out system.
4. After flushing system, turn off In-Line Pump.
5. Close ball valves at end of spray line.
6. Clean In-Line Filter.
7. Resume normal operation.
NOTE
: Lubricate the strainer basket lid seal with Vaseline to
ensure vacuum-tight seal.
Ball Valve
1-
1/2”
Elbow
(3.8 cm)
PVC Tee
Reducer
1 ¼” x 1 ¼” x 1
½”
To Water
Supply
Pump
Front View
Ball
Valve
Strainer
Basket
In-Line
Filter
NOTE
: Pads removed for
clarity.