![Cumberland AP Cumberland EDGE Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/cumberland/ap-cumberland-edge/ap-cumberland-edge_installation-manual_2698006025.webp)
Chapter 3: Basic Connections and Wiring
External connection
Rain sensor mounting
STEPS :
- Before unmounting the rain sensor, ensure the sensor is dry (no rain).
- Unscrew the 4 screws under the rain sensor.
- Pass the wire through the cable gland.
- Skin the 4 wires (orange, blue, white/orange and white/blue) at 0.2" (5mm).
- Cut the drain wire.
- Sensor wires must not exceed 100 feet (30.48 meters).
- Connect wire on terminal blocks like the diagram shown at right.
- Replace all the parts together and ensure that o-ring is in place. Re-install the
4 screws and tighten the cable gland.
Rain sensor connection
PROGRAMMING DIP
SWITCH
1
2
3
4
5
6
7
8
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
BL
OR
From EDGE weather
station module
2 x shielded twisted pairs
24 AWG (min) supplied with Rain
sensor unit (100 feet/30m)
WT/OR
WT/BL
NOTES :
- Make sure the Alignment Notch is pointing North.
- Bracket can be mount on a 1.5" SCH 80 PVC Pipe
- Ensure that there are no obstacles around the sensors for proper
sensing of the wind and rain.
NORTH
PNEG-2248
Weather Station
25
Содержание AP Cumberland EDGE
Страница 1: ...EDGE Weather Station Installation Manual PNEG 2248 Version 02 Date 05 12 19 PNEG 2248...
Страница 4: ...NOTES 4 PNEG 2248 Weather Station...
Страница 10: ...NOTES 10 PNEG 2248 Weather Station...
Страница 18: ...NOTES 18 PNEG 2248 Weather Station...
Страница 26: ...Chapter 3 Basic Connections and Wiring 26 PNEG 2248 Weather Station...
Страница 32: ...NOTES 32 PNEG 2248 Weather Station...