Chapter 3: Basic Connections and Wiring
Shield connection
2 x shielded twisted pairs
18 AWG (min), 600V,
Recommended cable type:
TC-ER / CIC
NOTES :
- Connect drain wire (shield) together when 2 cables enter in the same box as shown above.
- Don
’t tie shield from different bus together (AUTOMATION and SAFETY).
- At the end of the network, drain wire (shield) must be connect to Earth ground.
- Do not connect the shield at both end of the network to Earth ground.
Refer to Section
Grounding recommendations for the system
in the Instruction Manual for EDGE.
NOTES :
- At ONE end of the network, connect both shield of AUTOMATION and SAFETY network
together and to the terminal block for the EARTH ground connection.
- Don
’t connect the shield at both end of the network to EARTH ground.
- Make sure that the module is properly connected to EARTH ground.
- Usually, when a module is the last on the line, the switches must be in EOL position for both
network.
Shield connection in middle of the communication network
Shield at ONE end of the communication network
If the module is at one of the ends of the
communication network, the EOL switches
must be set (slide it to left) to the
corresponding EDGE communication bus
(AUTO (S1) or SAFE (S2)).
To EDGE Automation
communication bus
To EDGE Automation
communication bus
2 x shielded twisted pairs
18 AWG (min), 600V,
Recommended cable type:
TC-ER / CIC
To EDGE Safety
communication bus
2 x shielded twisted pairs
18 AWG (min), 600V,
Recommended cable type:
TC-ER / CIC
2 x shielded twisted pairs
18 AWG (min), 600V,
Recommended cable type:
TC-ER / CIC
To EDGE Safety
communication bus
2 x shielded twisted pairs
18 AWG (min), 600V,
Recommended cable type:
TC-ER / CIC
To EDGE Automation
communication bus
2 x shielded twisted pairs
18 AWG (min), 600V,
Recommended cable type:
TC-ER / CIC
To EDGE Safety
communication bus
From electrical
distribution panel
R
D
B
L
*
W
T
B
K
R
D
B
L
*
W
T
B
K
R
D
B
L
*
W
T
B
K
R
D
B
L
*
W
T
B
K
GN/YL
RD
BK
RD
BK
RD
BK
RD
BL*
WT
BK
RD
BL*
WT
BK
The color can differ depending on the
manufacturer of the cable.
NOTES :
Refer to Low voltage cable specifications
in the Instruction Manual for EDGE.
AP/Cumberland can provide sourced color-coded communication
wire to install EDGE controls. The wire will be available in both
16 and 18 gauge to accommodate the specified distance
between controls.
COLOR
RED
BLUE
COLOR CODE
RD
BL
ABBREVIATIONS
GREEN/YELLOW
GN/YL
BLACK
BK
WHITE
WT
ORANGE
OR
YELLOW
YL
WHITE/
ORANGE
WT/OR
WHITE/BLUE
WT/BL
BL*: could be Green instead of Blue
EOL resistor
24
PNEG-2248
Weather Station
Содержание AP Cumberland EDGE
Страница 1: ...EDGE Weather Station Installation Manual PNEG 2248 Version 02 Date 05 12 19 PNEG 2248...
Страница 4: ...NOTES 4 PNEG 2248 Weather Station...
Страница 10: ...NOTES 10 PNEG 2248 Weather Station...
Страница 18: ...NOTES 18 PNEG 2248 Weather Station...
Страница 26: ...Chapter 3 Basic Connections and Wiring 26 PNEG 2248 Weather Station...
Страница 32: ...NOTES 32 PNEG 2248 Weather Station...