External Modules Overview
External modules can be added to the basic EDGE system to extend its functionality by the RS485 links
(Automation or Safety).
EDGE RS485 Repeater
The EDGE RS485 Repeater allows you to extend the RS485 network and can also be used to add the
RS485 to different networks (T-Branch and H-Branch).
EDGE PSU 24V 36W
EDGE PSU 24V 36W is an external module which supplies external modules (EDGE Bin Scale, EDGE
Bird Scale, EDGE 2 Main Controller, EDGE 2 Controller Screenless, EDGE 2 Remote Display) in case
the Expansion Box power budget does not allow connexion directly on the EDGE Expansion Box.
EDGE Bin Scale (EDGE Bin Scale 3 Wires LC, EDGE Bin Scale 4 Wires LC
TB)
EDGE Bin Scale is an external module which allows the capability to collect and to analyze the weight of
feed in the bin. The module ensures the uninterrupted distribution of feed.
EDGE Bird Scale
EDGE Bird Scale is an external module which allows the capability to collect and to analyze the weight
data that come from the bird scales.
EDGE Power Module
EDGE Power Module is a variable outputs external module. The module allows the increasing of the
number of variables outputs on EDGE system. EDGE Power Module could contain up to 4 variables mod-
ules (EDGE Variable Output (SSR)). The 0-10Vdc outputs from Expansion Boxes control the variables
modules. The EDGE Power Module could be controlled by EDGE 8IN-4V-6REL FAILSAFE or EDGE 4IN-
12V.
NOTE:
The EDGE 4IN-12V can control up to 12 EDGE Variable Outputs, therefore it can control up to 3
EDGE Power Modules.
EDGE 2 Remote Display
EDGE 2 Remote Display is a remote which displays data on its screen from the main system by Ethernet
ports or allow the control of another EDGE 2 Main Controller. The EDGE 2 Remote Display is supplied by
24Vdc: Expansion Box or EDGE PSU 24V 36W. The EDGE 2 Remote display is optional and it is not
mandatory to use it in the EDGE network. EDGE 2 Remote Display replaces wireless or cellular devices
to control remotely locally.
EDGE 2 Controller Screenless
EDGE 2 Controller Screenless is an EDGE Main Controller except there is not LCD screen. It is only
accessible remotely.
NOTE:
The EDGE 2 Controller Screenless can only be used as a redundant Main Controller.
EDGE Weather Station
EDGE Weather Station provides the outside environmental parameters to the ventilation controller which
will correctly manage the ventilation system according to the outside parameters. The information from
the sensors is transmitted by the Weather Station to the ventilation controller by the RS485 bus. The
8
890–00687
EDGE 2
Содержание 064-11343
Страница 7: ...Chapter 1 Introduction Figure 1 2 Enclosure Identification 890 00687 EDGE 2 7...
Страница 22: ...NOTES 22 890 00687 EDGE 2...
Страница 30: ...Chapter 2 Pre Installation Planning 30 890 00687 EDGE 2...
Страница 40: ...NOTES 40 890 00687 EDGE 2...
Страница 58: ...NOTES 58 890 00687 EDGE 2...
Страница 98: ...NOTES 98 890 00687 EDGE 2...
Страница 112: ...NOTES 112 890 00687 EDGE 2...
Страница 116: ...NOTES 116 890 00687 EDGE 2...
Страница 120: ...NOTES 120 890 00687 EDGE 2...
Страница 134: ...NOTES 134 890 00687 EDGE 2...
Страница 135: ...F Extending a cable Best practice using a junction box 890 00687 EDGE 2 135...
Страница 136: ...Appendix F Extending a cable Using of heat shrink tubing 136 890 00687 EDGE 2...