Appendix C: Technical Specifications
Table C-8
6-Slot Expansion Box and 3-Slot Expansion Box ratings (cont'd.)
LED and CCFL loads
120/208/240Vac; 50/60Hz, 750W/ 920VA MAX
Minimum load of 0.2A / 25W
Ballast load
120Vac; 50/60Hz; 1200W; 10 MAX
208 Vac; 50/60Hz; 1040W; 5A MAX
240Vac; 50/60Hz; 720W; 3A MAX
Minimum load of 0.2A
Light Dimmer Outputs
INPUTS :
SUPPLY INPUT:100-120/220-240Vac ±10%,50-60Hz,1/2 phase(s)
OUTPUTS:
POWER OUTPUT(Per
channel):
– 100-120/220-240Vac 8.0Amps max
– 100-120Vac, 800-960VA, (CFL/CCFL, LED)
– 220-240Vac, 1760–1920VA, (CFL/CCFL, LED)
Table C-9
EDGE 4IN-2V-8DO ratings
DC Supply Input
18-24Vdc, 7.2W
Coils contactors/relays outputs
24Vac-240Vac, 0.5A max, 50/60Hz, PF max: 0There is
no security high temperature opening feature for natu-
ral inlets..35
Current sensors
Motor load current sensing
1 phase, 50/60Hz, PF max: 0.5
100-120Vac : 16FLA, 1HP
200-240Vac : 12FLA, 2HP
3 phases, 50/60Hz, PF max: 0.5
L-L : 208Vac : 10.56FLA, 3HP
L-L : 380Vac : 15.4FLA, 10HP
L-L : 415Vac : 15.4FLA, 10HP
General use load current sensing
120/208/240/380/415Vac, 16A, PF max: 0.75
Heating Load current sensing
120/208/240/380/415Vac, 16A, PF max: 1
Inputs
Temperature
Compliant to GSIE temperature probes
Accuracy of ±0.1ºC in a normal operation
Allowable loss of performance in a noisy environment:
Accuracy of ±0.65ºC from initial reading with a fixed resistor of 1% precision used for test-
ing purpose.
Analog 0-5 Volts
Sensor must be able to drive a 2k Ohms load, which means the sensor must drive at least
2.5mA to ensure correct readings.
Accuracy of ±30mV in a normal operation.
126
890–00687
EDGE 2
Содержание 064-11343
Страница 7: ...Chapter 1 Introduction Figure 1 2 Enclosure Identification 890 00687 EDGE 2 7...
Страница 22: ...NOTES 22 890 00687 EDGE 2...
Страница 30: ...Chapter 2 Pre Installation Planning 30 890 00687 EDGE 2...
Страница 40: ...NOTES 40 890 00687 EDGE 2...
Страница 58: ...NOTES 58 890 00687 EDGE 2...
Страница 98: ...NOTES 98 890 00687 EDGE 2...
Страница 112: ...NOTES 112 890 00687 EDGE 2...
Страница 116: ...NOTES 116 890 00687 EDGE 2...
Страница 120: ...NOTES 120 890 00687 EDGE 2...
Страница 134: ...NOTES 134 890 00687 EDGE 2...
Страница 135: ...F Extending a cable Best practice using a junction box 890 00687 EDGE 2 135...
Страница 136: ...Appendix F Extending a cable Using of heat shrink tubing 136 890 00687 EDGE 2...