26
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Service Check
The
service mode allows one to view the number of reconditioning cycles in the past 14 days, the total number
of reconditioning cycles the control has cycled through and the number of days since the last reconditioning cycle.
The
statistical functions are reached by pressing the “Status” key until the screen blanks and then pressing the
“-” key. Repetitive presses of the “-” key will cycle through the statistics mode. Pressing the “Status” key will exit
statistics and move to the time display. The following table outlines the statistic function display, range limits and
default setting:
Display
Range Limits
Comments
• Number of Reconditioning
Cycles - Last 14 days
0 to 99
- Days counter is to be updated at 12:00 AM ONLY
when dip #2 is on AND dip #4 is off; Otherwise
update at whatever TOR is set for
- Number of Reconditioning is to be updated after a valid
reconditioning is complete (cycle 3 times out automatically)
• Number of days
since last Reconditioning
Cycles
0 to 99
- Days counter is to be updated at 12:00 AM ONLY
when dip #2 is on AND dip #4 is off; Otherwise,
update at whatever TOR is set for
- After a valid reconditioning is complete
(cycle 3 times out automatically), the counter is to be reset to 0
• Number of Reconditioning
Cycles - Life of the Unit
0 to 9,999
Counter is to be updated after completion
of valid reconditioning cycle. (cycle 3 times out automatically)
• To be saved in EEPROM before the control is powered down during a power outage.
Once the statistics menu is entered the information shown for each display is outlined below:
•
“Regen” key is always ignored in statistics mode
•
Can enter directly into diagnostics mode by pressing the “+” key
•
When returning to statistics mode directly from diagnostics mode, always display the first statistic in the
list as if statistics mode was entered for the first time (don’t have to remember where it left off in the list)
•
Can exit back to service mode by pressing the “status” key
•
Automatically times out back to service mode after 10 minutes of no key press activity
•
Drop all leading zeros