Circuit Board Troubleshooting
43
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Test Description
Display Information
Action Trigger
Status Key
Display to show “11”
Press Status Key
+ Key
Display to show “12” and motor to run for 15 seconds
Press + Key
- Key
Display to show “13” (and turns on Chlorinator
output for 15 seconds IF chlorinator is connected)
Press - Key
Regen Key
Display to show “14”
Press Regen Key
Home Switch
Display to show “H” when Home switch closed
Close Home Switch
Display to Blank when open
Open Home Switch
Position Switch
Display to show “P” when Position switch closed
Close Position Switch
Display to Blank when open
Open Position Switch
Flow Meter
Display to show “Phone” icon when flow meter is
connected
Connect Flow Meter
Display to blink “Phone” icon when flow meter is
sending pulses
Spin Flow Meter
Chlorinator
Display to show “Colon” icon when chlorinator is
connected
Connect Chlorinator
Display to blink “Colon” icon when chlorinator is turned
on
Turn on Chlorinator when the plus
key is pressed.
When exiting test mode, if the dip switches or sensors have not changed, the control is to restore all values from
EEPROM, and resume where it left off after homing. If the dip switch or sensors have change, the values should reset
to factory defaults. In either case the valve should home itself upon exit of test mode.