Installation
11
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Filter Media Loading – Sulfur-OX3
Table 2. Sulfur-OX3 Media Quantities.
Size
Cullsan (lb)
Cullar S (ft³)
Freeboard (inches)
10” Filter
20
1.0
29
NOTE!
Cullar S Catalytic Activated Carbon media must be soaked for 24-48 hours before being put into service.
In-plant prep is highly recommended.
1.
Position the tank in the desired installation location.
2.
Remove the inlet strainer by turning it
counter-clockwise.
3.
Position the outlet manifold in the tank.
4.
Cover the top of the manifold with a clean rag to prevent
filter media from entering the manifold during filling.
5.
Using a large-mouth funnel, load the Culligan Cullsan
underbedding through the top of the tank. See
6.
Load the tank with Cullar S media.
Leveling is required. See
7.
Remove the funnel.
8.
Using a hose, top off the tank with water to bring
the water level to within a few inches of the top
opening and add 2 ounces of 6% liquid chlorine
bleach to the tank for sanitization.
9.
Install the inlet strainer making sure to thread the
strainer until it bottoms out on the tank thread.
Failure to install the strainer correctly can cause
the control to leak.
CAUTION!
Once the tank is full do not lay it down as
this will disrupt the filter media and result
in poor performance.
CAUTION!
DO NOT allow the outlet manifold
to move when loading the media.
The manifold must remain vertical
to ensure a good seal at the o-ring.
Figure 4.
Iron-OX5 Media Tank Cross Section
Distributor
Manifold
Cullsan
20 lb
Freeboard
(±29")
Wide
Mouth
Funnel
Inlet
Strainer
Cullar S Catalytic
Carbon, 1ft³