4/16
Logika - use and maintenance guide
page
The technical specifications in the chart below are given for the models according to the type
of refrigerant used.
Description
Unit
Measure
R12
Values
R134a
Values
Max. absorbed power
W
800
800
Net weight
Kg
81
81
Overall dimensions (HxLxP)
Mm
1040x540x600
1040x540x600
Fully charged weight
kg
100
100
Vacuum flow rate
lt/min
66
66
Max. vacuum
mbar
0.01
0.01
Filter absorption capacity (rate)
gr H2O
80
80
System recovery rate
gr/min
400
400
Refrigerant cylinder capacity
kg
10
10
Supply voltage
V
220/240
220/240
Supply frequency
Hz
50
50
Max. absorbed current
A
5,0
5,0
Coupling diameter on vehicle (Low Pressure LP)
mm
11
13
Coupling diameter on vehicle (High pressure HP)
mm
11
16
Max. operating temperature
°C
50
50
Min. operating temperature
°C
5
5
Max. pressure pneumatic circuit
bar
18
18
2. Technical characteristics
For supply voltage, always use the value indicated on the machine plate.
The acoustic pressure value for the machine is below 70dBA and therefore no special
precautions need to be taken by the operator even in the case of continuous use
(standard ISO 3746). However, it is the responsibility of the employer to evaluate
noise level exposure of workers in compliance with the directives concerning work
hygiene and safety.
Содержание Logika
Страница 1: ...LOGIKA USE AND MAINTENANCE GUIDE...