Logika - use and maintenance guide

3/16

page

The machine described in this user and maintenance guide is an automatic, multifunctional 

digital-setting system for operation with vehicle air conditioning (A/C) plants with functions 

for gas recovery, used oil discharge, vacuum, leakage control, oil injection and gas 

injection, all managed by a microprocessor and an electronic precision scale. 

Do  not  use  the  machine  for  any  purpose  other  than  which  it  was  designed.             

In the case of demolition or hauling away, check the legislation codes that are 

applicable in your Country (note that the machine contains refrigerant fluids and 

we therefore recommend demolition by specialised operators).

The  machine  is  supplied  with  two  distinct  models  for  two  types  of  refrigerant.    

Do not use the same model for both types of fluids.

1.  Introduction

•  

Electronic management system

: it allows the whole process to be administered through

    a microprocessor.
•  

Electronic precision scale for weighing of gas

: it can weigh up to a maximum of 10 Kg.

     of refrigerant with a margin of error of 10 grams and is programmed to interrupt the

     RECOVERY and CHARGING functions if pre-set for this purpose or should the quantity of

     gas exceed the set limits.
•  

Electronic precision scale for weighing of oil injection

: it can weigh up to a

     maximum of 500 grams with a margin of error of 10 gr.
•  

Compressor for refrigerant gas recovery

.

•  

Anti-acid and dehydration filters

 (n. 3) with hight absorption capacity of water

     guaranteeing excellent autonomy.
• 

Infeed gas still

 with automatic regulation of refrigerant flow and separated oil coming

     from the A/C system with discharge of oil coming from the same.
•  

Oil separator

: positioned immediately after the compressor with automatic oil return at

    the end of the cycle.
•  

Cylinder for refrigerant gas recovery

, equipped with an electronically controlled

     thermostatic resistor and discharge of incondensable gases.
•  

Two-stage high-performance vacuum pump

.

•  

Control panel

 with digital commands.

•  

Analogic pressure gauges

.

•  

Refrigerant service valve (Ref. Service)

: allows refrigerant contained in the internal

     cylinder of the unit to be sent to a suitable outside container for the purpose.
•  

Solenoid valve

 for the discharge of the incondensable gas which are in the bottle.

•  

Discharge valve

 

for oil coming from the A/C system

.

•  

High-performance flexible hoses

 (n. 2) with rapid coupling and with manual opening

    (screw mechanism) for R134a and R12.
•  

Oil dosing devices

 (n. 2) 500 cc.

Содержание Logika

Страница 1: ...LOGIKA USE AND MAINTENANCE GUIDE...

Страница 2: ...t the machine is used for a purpose other than that for which it was intended or is tampered with by persons not authorised by our company or in any case using non compliant methods or parts The Compa...

Страница 3: ...ilters 15 15 3 Oil containers 15 4 Charging and service hoses 15 5 Spare parts 16 Labels SYMBOLS KEY DANGER indicates situations or problems that can be a safety risk and an accident or life threateni...

Страница 4: ...G functions if pre set for this purpose or should the quantity of gas exceed the set limits Electronic precision scale for weighing of oil injection it can weigh up to a maximum of 500 grams with a ma...

Страница 5: ...V 220 240 220 240 Supply frequency Hz 50 50 Max absorbed current A 5 0 5 0 Coupling diameter on vehicle Low Pressure LP mm 11 13 Coupling diameter on vehicle High pressure HP mm 11 16 Max operating te...

Страница 6: ...ng normal operating phases unless expressly stated in the instructions Always wait some minutes after having switched off the machine to allow the system to be correctly reset temperature and pressure...

Страница 7: ...is equipped with the prescribed safety devices in accordance with the relevant codes in force differential circuit breaker mechanism and earthing grounding system We advise you to follow the instruct...

Страница 8: ...tion 4 High pressure gauge 30 bar 11 Ref Service coupling 5 LP valve low pressure 12 Low pressure connection Blue 6 HP valve high pressure 13 High pressure connection Red 7 Oil injection tank connecti...

Страница 9: ...in vacuum control cycle E6 Insufficient quantity of refrigerant for programmed charge E7 Refrigerant oil charge time expired E9 Insufficient quantity of oil injection Possible error codes 7 Menu struc...

Страница 10: ...Terminated the pressure in the A C system the display visualizes T200 seconds for eventual refrigerant still blocked in the system in the form of micro frozen granules of oil and humidity At the end...

Страница 11: ...ys Press the OK key to proceed with the vacuum function If the pre set time doesn t decrease after 10 minutes the function will stop and the error code E4 will appear time to achieve vacuum expired Ch...

Страница 12: ...nd the led START lights on to start the charging operation fig 3 During the oil and gas charging the display visualizes the grams with a margin of error of 10 gr Oil will be charged only after the vac...

Страница 13: ...vacuum phase If at the end of this phase it is not possible to close the LP valve once the charging operation has come to an end wait for three minutes before starting the A C system or in case of on...

Страница 14: ...ammed for recovery E2 Recovery time expired E3 Pressure present in the system at the start or during the vacuum cycle E4 Time to achieve vacuum expired E5 Leaks found in vacuum control cycle E6 Insuff...

Страница 15: ...gas left in the hose Check the oil level in the vacuum pump every three months Change the oil in the vacuum pump every six months even when the unit is not used regularly Check the calibration of the...

Страница 16: ...al sheets on request The machine is supplied with connecting hoses to the A C plant of length equal to 1800 mm Should the standard tubing not be of sufficient length for your requirements tubing lengt...

Страница 17: ...by CTR Group S p A all rights reserved CTR Group s p a Via T ed E Manzini 9 43100 Parma Italy Tel 39 0521 957611 Fax 39 0521 957677 internet http www ctrgroup it e mail ctrgroup ctrgroup it...

Отзывы: