12/16
Logika - use and maintenance guide
page
How to empty the hoses of the unit:
- After having carried out the charging procedure, maintain the high and low pressure
hose connections but close the two
HP
-
LP
valves, start the vehicle engine and wait a few
minutes until the A/C plant is fully running.
- In case of only one service point, close the
HP
or
LP
valve used and disconnect the hose
from the vehicle.
- In case of two service points, disconnect the high pressure (
HP
) hose from the vehicle
and open the two valves
HP
-
LP
on the control panel to allow the gas contained in the
hoses to be discharged through the low pressure terminal to the vehicle. Wait until
HP
and
LP
fall to about 2 bar, then disconnect the remaining low-pressure hose (
LP
).
Switch off the engine.
This procedure allows the system to carry out gas recovery, recovered oil discharge, vacuum,
leakage control, oil charge and gas charge in a completely automatic mode and with invariable
times for each operation respect to the manual mode.
- Connect up the high and low pressure hoses.
- Open the
HP
and
LP
valves; we advice you to close the
LP
valve at the end of the
vacuum phase. If at the end of this phase it is not possible to close the
LP
valve, once
the charging operation has come to an end, wait for three minutes before starting the
A/C system, or, in case of only one service point, open the corresponding valve.
- Use the
SEL
key to select
AUTOMATIC
, indicated by the lateral led light (fig. 1).
- Once the
AUTOMATIC
operation has been selected, the led
OIL
position on the display
lights on and the programmed quantity 30 gr. (indicated as 0030) of fresh oil appears on
the display (fig. 1). This quantity can be changed by using the “
+
” and “
-
” keys.
- Press the
OK
key to confirm.
- The led light
OIL
disappears and the led
GAS
position lights on. The programmed
quantity 700 gr. (indicated as 00.70 kg) appears on the display and it can be changed
by using the “
+
” and “
-
” keys (fig. 2).
- Press the
OK
key to confirm.
- The led
GAS
disappears and the led
START
lights on to start the Automatic operation (fig. 3).
- If the quantity of oil and refrigerant are lower than the minimum quantity, the error
codes
E6
-
E9
will be visualized to indicate that you must restore the levels before
starting the operation, then re-select the
AUTOMATIC
phase.
- During the operation, the display will visualize times, quantities and errors of the different phases.
11. “AUTOMATIC” operation
1- Setting oil charging
2- Setting gas charging
3- Start operation