Take the red high-pressure hose HP; remove the rapid coupling at its end, 

connect the hose to an external cylinder containing refrigerant and carry out 

the recovery procedure (see the section Manual operation “RECOVERY”). 

If the external cylinder is not equipped with an internal pick-up 

tube, it should be turned upside down so that the gas flows out in 

a liquid state. We would recommend that the pressure value be 

maintained at approximately 3 bar at this stage of recovery visible 

on the HP pressure gauge by partially opening the valve on the 

external cylinder

. When the desired quantity has been reached, close the 

valve of the external bottle and wait for the end of recovery operation. Then 

disconnect the hose and re-screw the rapid coupling.

     To carry out emptying of the cylinder the operator should:
-    Switch on the machine, connect a service hose with the 

Ref. Service

 valve and the other

     end of the hose with a bottle or another external container; open the valves. 

-   Once the transfer has come to an end, close the valves and carry out the recovery

     operation of the gas left in the hose.

-    Check the oil level in the vacuum pump every 

three

 months.

-    Change the oil in the vacuum pump every 

six

 months even when the unit is not used regularly.

-    Check the calibration of the scale.

To top up or change oil in the vacuum pump, the operator should use oils that are designed 

for use in vacuum pumps.

To top up

, the operator should unscrew the cap of the vent (see 

illustration) and top up with sufficient oil to the level of the screw of 

the indicator light. Finally, replace the cap on the vent.

To do a complete oil change

 it is necessary to:

-  run the pump for 10 minutes;

-  disconnect the machine from the power supply;

-  disassemble the drainage cap positioned on the underside of the

   pump; wait until all the oil has drained out, and replace the cap;

-  unscrew the vent cap and fill up with new oil  until the level is 

   halfway up the spyglass;

-  replace the vent cap.

13.  Recharging of the gas storage cylinder

14.  Refrigerant transfer from the unit to an external container

15.  General maintenance

15.1  Topping up or changing oil in the vacuum pump

Periodically:

The station is equipped with a recovery cycle counter; when the filters 

are saturated, every time the unit is switched on, a display with the 

word “FILT” will indicate that they need to be changed shortly. 

Contact our after-sales service centre.

Содержание Logika

Страница 1: ...LOGIKA USE AND MAINTENANCE GUIDE...

Страница 2: ...t the machine is used for a purpose other than that for which it was intended or is tampered with by persons not authorised by our company or in any case using non compliant methods or parts The Compa...

Страница 3: ...ilters 15 15 3 Oil containers 15 4 Charging and service hoses 15 5 Spare parts 16 Labels SYMBOLS KEY DANGER indicates situations or problems that can be a safety risk and an accident or life threateni...

Страница 4: ...G functions if pre set for this purpose or should the quantity of gas exceed the set limits Electronic precision scale for weighing of oil injection it can weigh up to a maximum of 500 grams with a ma...

Страница 5: ...V 220 240 220 240 Supply frequency Hz 50 50 Max absorbed current A 5 0 5 0 Coupling diameter on vehicle Low Pressure LP mm 11 13 Coupling diameter on vehicle High pressure HP mm 11 16 Max operating te...

Страница 6: ...ng normal operating phases unless expressly stated in the instructions Always wait some minutes after having switched off the machine to allow the system to be correctly reset temperature and pressure...

Страница 7: ...is equipped with the prescribed safety devices in accordance with the relevant codes in force differential circuit breaker mechanism and earthing grounding system We advise you to follow the instruct...

Страница 8: ...tion 4 High pressure gauge 30 bar 11 Ref Service coupling 5 LP valve low pressure 12 Low pressure connection Blue 6 HP valve high pressure 13 High pressure connection Red 7 Oil injection tank connecti...

Страница 9: ...in vacuum control cycle E6 Insufficient quantity of refrigerant for programmed charge E7 Refrigerant oil charge time expired E9 Insufficient quantity of oil injection Possible error codes 7 Menu struc...

Страница 10: ...Terminated the pressure in the A C system the display visualizes T200 seconds for eventual refrigerant still blocked in the system in the form of micro frozen granules of oil and humidity At the end...

Страница 11: ...ys Press the OK key to proceed with the vacuum function If the pre set time doesn t decrease after 10 minutes the function will stop and the error code E4 will appear time to achieve vacuum expired Ch...

Страница 12: ...nd the led START lights on to start the charging operation fig 3 During the oil and gas charging the display visualizes the grams with a margin of error of 10 gr Oil will be charged only after the vac...

Страница 13: ...vacuum phase If at the end of this phase it is not possible to close the LP valve once the charging operation has come to an end wait for three minutes before starting the A C system or in case of on...

Страница 14: ...ammed for recovery E2 Recovery time expired E3 Pressure present in the system at the start or during the vacuum cycle E4 Time to achieve vacuum expired E5 Leaks found in vacuum control cycle E6 Insuff...

Страница 15: ...gas left in the hose Check the oil level in the vacuum pump every three months Change the oil in the vacuum pump every six months even when the unit is not used regularly Check the calibration of the...

Страница 16: ...al sheets on request The machine is supplied with connecting hoses to the A C plant of length equal to 1800 mm Should the standard tubing not be of sufficient length for your requirements tubing lengt...

Страница 17: ...by CTR Group S p A all rights reserved CTR Group s p a Via T ed E Manzini 9 43100 Parma Italy Tel 39 0521 957611 Fax 39 0521 957677 internet http www ctrgroup it e mail ctrgroup ctrgroup it...