Number
of Flashes
Battery Low
The batteries are running low.
•
Recharge the batteries.
Low Battery Fault
The batteries have run out of charge.
•
Recharge the batteries.
•
Check the battery and associated connections
and wiring.
High Battery Fault
Handling method:
1.Disconnect the battery pack, and check
the battery condition.
2.
SERVICE-6
Battery Pack Repair.
Current limit time-out or controller
overheat
Do not drive up steep slopes or overload
the scooter.
N-D lever not set to D-position
Electromagnetic brake failure
Switch to D (drive) position. Turn off the power and
turn on again.
SERVICE-13-5
Electromagnetic Brake Repair.
The throttle is not in Neutral or the
folding / unfolding procedure is
uncompleted.
Solution:
1. Repeat the folding or unfolding procedure.
2.
SERVICE-1-3
Starter VR Repair.
The folding / unfolding procedure is
uncompleted
Repeat the folding or unfolding procedure.
Scooter battery is being charged
Turn off the main power and disconnect the
charger.
Micro switch failure
SERVICE-12-1
Micro Switch Repair.
Speed pot
SERVICE-1
Steering Cover Repair.
Motor or relevant circuit failure
Solution:
1.
SERVICE-11-1
DR Controller Repair
2.
SERVICE-13-4
Motor Repair
Main cable, controller failure or
controller temperature too high
Solution:
1.
SERVICE-11-1
DR Controller Repair
2.
SERVICE-2-1
Main Cable Repair
Possible Cause
Handling Method
1
2
3
4
5
6
7
8
9
Service manual
19
Self-Diagnostic Warning Light :
Self-Diagnostic Warning Light
When the main power switch is turned on (4-2 Main power Switch Operation), The self-diagnostic warning
light will flash if there be any malfunction or failure.
Touch Version-self-diagnostic warning light, shared
with the battery indicator.
Manual Version-self-diagnostic warning light, shared
with the main power light.
Normal : remains on, as does the battery power
indicator.
Failure : flashes according to the nature of the
failure, see the table below.
Normal : constant green light.
Failure : flashes according to the nature of failure,
refer to the table below.
Содержание HS-268
Страница 3: ...1...
Страница 4: ...2...
Страница 5: ...3 Manual...
Страница 6: ...4 Automatic...
Страница 7: ...5 Manual...
Страница 8: ...6 Automatic...
Страница 9: ...7...
Страница 10: ...8...
Страница 11: ...9...
Страница 12: ...10 Manual...
Страница 13: ...11...
Страница 14: ...12 Automatic...
Страница 15: ...13...
Страница 16: ...14...
Страница 17: ...15...