background image

Chapter 4.  Provisioning 

38 

admin@iSAP5100(slot-1/16e1-1) 

sensitivity

 

high

 

 
 
 
Set E1impedance to 75 ohm 

admin@iSAP5100(slot-1/16e1-1)

 impedance 75ohm 

 

 

4.8.2 

E1 card BERT setup  

Enable BERT function. 

admin@iSAP5100(slot-1/16e1-1) 

bert enable 

 
 
Insert BERT errors. 

admin@iSAP5100(slot-1/16e1-1)

 bert err-ins 

 

 none            1e-1            1e-3            1e-4            1e-5 

 
 
Clear BERT. 

admin@iSAP5100(slot-1/16e1-1) 

bert clear 

 
 
Set up BERT pattern. 

admin@iSAP5100(slot-1/16e1-1)

 bert pattern  

2e7-1 

 

2e9-1 

 

2e11-1 

 

Содержание iSAP5100

Страница 1: ...1 iSAP5100 Integrated Service Access Platform ...

Страница 2: ...ssociated with such unintended or unauthorized use even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product WARNING This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference...

Страница 3: ...7 This manual supports the following models iSAP5100 This document is the current official release manual Please check CTC Union s website for any updated manual or contact us by E mail at sales ctcu com Please address any comments for improving this manual or to point out omissions or errors to marketing ctcu com Thank you 2017 CTC Union Technologies Co Ltd All Rights Reserved The contents of thi...

Страница 4: ...SAP FXS Card 12 1 3 10 iSAP E M Card 12 1 3 11 iSAP G703 64K Card 13 1 3 12 iSAP RS232 Card 13 1 3 13 iSAP RS232 C Card 13 1 3 14 iSAP ET100 Ethernet Bridge Line Card 13 1 3 15 iSAP N x 64K Card 13 CHAPTER 2 PANEL DESCRIPTIONS 14 2 1 5100 MS DM CARD 14 2 1 1 5100 MS DM 96 Card 14 2 1 2 5100 MS DM 155 Card 14 2 2 ISAP FOM CARD 15 2 2 1 iSAP FOM01 Card 15 2 2 2 iSAP FOM02 Card 16 2 3 ISAP E1 CARD 17...

Страница 5: ...ONS 34 4 2 1 E1 Cross Connect to SDH 34 4 2 2 IO Card Cross Connect to E1 34 4 2 3 IO Card Cross Connect to E1 in SDH 34 4 3 MIRRORING AN E1 CHANNEL 35 4 4 BROADCAST E1 35 4 4 1 Configure Broadcast Source 35 4 4 2 Configure Broadcast Listener 35 4 5 CONFIGURING REDUNDANCY 36 4 5 1 Optical Port Redundancy Setup 36 4 5 2 E1 Redundancy Setup 36 4 6 SNMP MANAGEMENT 36 4 6 1 SNMP Setup 36 4 6 2 IP Addr...

Страница 6: ... selected according to needs The modules can be plugged into any of the 18 available card slots according to specific maintenance and application methods All time slots may be user defined iSAP5100 supports SNMP network management When SNMP management mode is available and selected the Web based GUI provides an intuitive and easy to use graphical interface to provision and monitor all operations o...

Страница 7: ...ys in a working state and minimizing any loss due to management downtime Figure 2 Rear View The rear of the chassis offers 18 slots in total E1 cards can be inserted in Slot 1 6 which support 16 channel E1 Slot 7 18 are extension slots for E1 which support 4 channel 8E1 16E cards IO cards including FXO card FXS card E M card G703 64K card RS232 card R232 C card N 64K card ET100 card RS485 card can...

Страница 8: ...atistics STM 1 Alarm indication LOS LOF RDI HP AIS HP LOP LP AIS LP LOP BER B1 B2 B3 E1 Alarm indication LOS LOF AIS RAI BER FRR CRC Support BERT line loopback test function Support the flexible clock synchronization function Support any one of 144 E1 lines as recovery clock source The management card supports card failover backup function The management card supports card failover with switching ...

Страница 9: ...ors Each channel s speed is 64Kbps and supports local and remote loopback test 1 2 10 iSAP RS232 Card Each card supports 6 port RS232 connector Each port supports speed of 38 4kbps asynchronous Each port supports speed of 2 4 4 8 9 6 19 2 38 4 64kbps synchronous DCE interface Supports local and remote loopback test 1 2 11 iSAP RS232 C Card Each card supports 6 port RS232 connector Each port suppor...

Страница 10: ...ch other NMS interface Ethernet 10 100Base TX RJ45 Auto Negotiation Console port Serial RS232 interface DB9 Female Cross connect capacity 144 E1 has no non blocking exchange 155M fiber 63E1 and 144 E1 have no non blocking exchange Support the replication of E1 time slot broadcast function CAS signaling exchange Cross connect between CAS signals of 16 timeslots and voice timeslots STM 1 E1 multiple...

Страница 11: ...ck Speed 2 048Mbps Interface RJ45 or BNC transfer to BNC via RJ45 Line Coding HDB3 AMI Rx Sensitivity 20 43dB Line Impedance 75 ohm unbalanced 120 ohm balanced Level Range 2 37V 75 ohm 3 00V 120 ohm Jitter Performance Comply with ITU G 823 equipped with jitter attenuator ITU Standards G 703 G 704 G 732 G 823 Internal BERT test 1 3 7 iSAP 16E1 Card Frame Format CAS PCM30 CCS PCM31 Unframe CRC ON OF...

Страница 12: ... Frequency 0 5dB Idle Channel 70dB AD TX Gain 0dB DA RX Gain 3 5dB ITU T Standards G 712 G 713 G 714 1 3 10 iSAP E M Card Signaling E circuit M circuit are used as the inter office signaling of the control circuit interface transmission Provides E circuit M circuit SB Battery and SG Earth lines Range of Loop Current 5 30 mA maximum 70 mA Each E M channel can provide 5 signaling modes TYPE1 TYPE5 E...

Страница 13: ...ts 6 DCE interface Cable DB62 to DB25 1 3 13 iSAP RS232 C Card Data Rate 38 4kbps Async 2 4 4 8 9 6 19 2 38 4 64 128kbps Sync 2 4 4 8 9 6 19 2 38 4 64bps Independent clock Connector V 24 RS 232 Loopback Local loopback Remote loopback Ports 6 DCE interface Cable DB62 to DB25 1 3 14 iSAP ET100 Ethernet Bridge Line Card Connector RJ45 Ports 4 ports Loopback Local loopback Remote loopback Data Rate 10...

Страница 14: ...ALM Red On The management card detects a minor alarm indication Off The board operates normally 2 Active Green Blinking This indicates the SNMP kernel is alive and running normally Off No data transmission Link Green On This indicates a good link Blinking This indicates data transmission Off This indicates no link 3 SLOT1 18 Yellow Green Off This indicates no card installed or not yet configured Y...

Страница 15: ...he SNMP kernel is alive and running normally Off No data transmission Link Green On This indicates a good link Blinking This indicates data transmission Off This indicates no link 4 SLOT1 18 Yellow Green Off This indicates no card installed or not yet configured Yellow This indicates the slot is working abnormally Green This indicates the slot is installed and working normally without alarms 2 2 i...

Страница 16: ...nvert RJ45 to BNC Position LED Color Status Description 1 PWR Green On The power board operates normally Off The power board is abnormal 2 ALM Red On Abnormal conditions occur Off The system operates normally 3 OP1 L Green On Optical signals received Off Optical signals not received 4 OP2 L Green On Optical signals received Off Optical signals not received 5 OP1 A Green On Optical signals received...

Страница 17: ... On E1 LOS for that channel Blinking E1 LOF for that channel Off Normal operation 2 3 2 iSAP 16E1 Card 1 Power indicator LED 2 Alarm indication for the module 3 E1 alarm LEDs CH1 CH16 4 RJ45 connector Each RJ45 is wired for 2 E1 channels An adapter cable is optional to convert to BNC 5 Thumb screws This is used to secure the card in the chassis slot Position LED Color Status Description 1 PWR Gree...

Страница 18: ...4 2 iSAP RS232 C Card 1 Power indicator LED 2 Alarm indication for the module 3 Transmit Data LEDs CH1 CH6 4 Receive Data LEDs CH1 CH6 5 DB62 connector Use DB62 to DB25 adapter cable to produce six RS232 interfaces Position LED Color Status Description 1 PWR Green On The power board operates normally Off The power board is abnormal 2 ALM Red On Abnormal conditions occur Off The system operates nor...

Страница 19: ...H1 CH8 4 RJ45 connectors supporting 8 E M ports 5 Thumb screws It is used to secure the card in the chassis slot Position LED Color Status Description 1 PWR Green On The power board operates normally Off The power board is abnormal 2 ALM Red On Abnormal conditions occur Off The system operates normally 3 CH1 CH8 LED Green Blinking Signaling Signals alarm Civil Aviation Signals alarm Blinking rapid...

Страница 20: ...cation for the module 3 Channel LEDs for CH1 CH8 4 RJ45 connectors supporting 8 x FXS interfaces 5 Thumb screws It is used to secure the card in the chassis slot Position LED Color Status Description 1 PWR Green On The power board operates normally Off The power board is abnormal 2 ALM Red On Abnormal conditions occur Off The system operates normally 3 CH1 CH8 LED Green Blinking Signals alarm On S...

Страница 21: ...530 RS449 X 21 connector LED Indicators Position LED Color Status Description 1 PWR Green On The power board operates normally Off The power board is abnormal 2 ALM Red On Abnormal conditions occur Off The system operates normally 3 TX LED for CH1 CH4 Green Off TX is unused or not connected On TX connection is normal but data is not transmitted Blinking TX data transmitted 4 RX LED for CH1 CH4 Gre...

Страница 22: ...Chapter 2 Panel Descriptions 22 Power indicator AC or DC power connector Power Switch Position LED Color Status Description 1 PWR Green On Power on Off Power off ...

Страница 23: ...installed This will lessen the possibility of injury should a fully loaded chassis be dropped 3 2 Install the Management Card The two horizontal slots in front of the chassis accept the management cards either the MS DM 96 or the MS DM 155 To help in seating and removing the management cards release levers are deployed at far left and right Release or insert boards with equal force on these two le...

Страница 24: ...available in multimode or in single mode with different distance reach 3 3 E1 Card E1 cards are available in two types 8E1 and 16E1 card E1 cards must be placed in slot 1 6 starting at Slot 1 to Slot 6 if six cards are installed The E1 board had 4 or 8 RJ45 interfaces respectively for 8E1 or 16E1 card Each RJ45 supports two pairs of 4 wire bi directional E1 signals Special RJ 45 to coaxial adapter...

Страница 25: ... and pull straight back with equal force to unseat the IO card 3 4 1 FXO Card Pinouts RJ45 Pin RJ11 4PIN Signal Definition 4 2 2W Line A 5 3 2W Line B 3 4 2 FXS Card Pinouts RJ45 Pin RJ11 4PIN Signal Definition 4 2 2W Line A 5 3 2W Line B 3 4 3 E M Card Hardware Setup DIP SWITCH 1 E M Card Working Mode Setup On the board there are two DIP switches S1 S2 for setting up the working mode The mapping ...

Страница 26: ...ype 1 Type 2 Type 3 Type 4 Type 5 S3 A A A B B S6 A A A B B S5 A A A B B S4 A A A B B 3 E M Card Cabling RJ45 Pin Signal Definition Voice Signal 1 TIPA 4 Wire input 2 RINGA 4 Wire input 3 TIPB 2 Wire 4 Wire output 4 RINGB 2 Wire 4 Wire output E M Signal 5 E Output 6 M Input 7 SG 8 SB 3 4 4 RS232 RS232 C Card Pinouts HDB62 M DB25 F 1 Signal Definition 44 2 TD 22 3 RD 1 4 RTS 3 5 CTS 6 DSR 107 43 7 ...

Страница 27: ...C 51 17 RC 31 20 DTR 30 24 ETC DB25 F 4 53 2 TD 12 3 RD 32 4 RTS 34 5 CTS 6 DSR 35 7 GND 55 8 CD 33 15 TC 54 17 RC 14 20 DTR 13 24 ETC DB25 F 5 56 2 TD 36 3 RD 15 4 RTS 17 5 CTS 6 DSR 18 7 GND 58 8 CD 16 15 TC 57 17 RC 38 20 DTR 37 24 ETC DB25 F 6 59 2 TD 19 3 RD 39 4 RTS 41 5 CTS 6 DSR 42 7 GND 61 8 CD 40 15 TC 60 17 RC 21 20 DTR 20 24 ETC ...

Страница 28: ...nel 2 Channel 3 Channel 4 Shield Shield Shield Shield A Shield PG 17 18 51 52 B SG 1 19 35 53 R RD A 2 20 36 54 T RD B 3 21 37 55 V RC A 4 22 38 56 X RC B 5 23 39 57 Y TC A 6 24 40 58 AA TC B 7 25 41 59 P TD A 8 26 42 60 S TD B 9 27 43 61 U ETC A 10 28 44 62 W ETC B 11 29 45 63 H DTR 15 33 49 67 C RTS 13 31 47 65 F DCD D CTS E DSR XX A and XX B must be a pair of twisted pair cable Note V35PIN F D ...

Страница 29: ... must be a pair of twisted pair cable Note DB25 PIN 8 5 6 are shorted PIN 10 13 22 are shorted X 21 Cable 68Pin Male Pin X 21 DB15 Pin Function Channel 1 Channel 2 Channel 3 Channel 4 Shield Shield Shield Shield 1 Shield PG 17 18 51 52 8 SG 1 19 35 53 4 R A 2 20 36 54 11 R B 3 21 37 55 6 S A 4 22 38 56 13 S B 5 23 39 57 6 24 40 58 7 25 41 59 2 T A 8 26 42 60 9 T B 9 27 43 61 10 28 44 62 11 29 45 6...

Страница 30: ...B must be a pair of twisted pair cable Note DB37 PIN 13 11 9 are shorted PIN 31 29 27 are shorted 3 5 Alarm Relay Connections Alarm indication connectors are on the rear of the chassis which are shown as follows Minor ALM OFF Normally open When a minor alarm occurs it closes ON Normally closed When a minor alarm occurs it opens COM Common connection contact Major ALM OFF Normally open When a major...

Страница 31: ... the management cards on the front of the chassis Four thumb screws secure the modules A single module can be hot swapped while the other module provides power to the chassis in a non stop fashion Two working modules provide redundancy in case one module fails Power Module Power Module ...

Страница 32: ... the other end to the COM port in your management PC Configure the terminal as follows 115200bps 8 N 1 After powering on iSAP5100 the device starts to work and initiate Welcome To iSAP5100 Console Management Interface configuration files read and write Init hardware Init software User Verification Login slot 1 insert BOARD_16E1 slot 5 insert BOARD_FXS slot 11 insert BOARD_EM ...

Страница 33: ...system system dev info Current time 04 03 2014 13 45 53 hostname iSAP5100 syscontact syslocation Hardware Version 1 30 Software Version 1 31 CPLD Version 1 01 FPGA Version 1 04 64M bytes DRAM 64M bytes Flash working clock 16e1 slot 1 port 3 set clock 16e1 slot 1 port 1 system status info cpuslot 1 CUPA working PM5320_A normal PM8316_A normal more q for quit others for continue 4 1 3 E1 Framing Con...

Страница 34: ...0 cross Configure cross connect to VC12 admin iSAP5100 cross e1 cross src slot 1 src port 1 1 31 vc12e1 1 1 31 4 2 Multiplexing Configurations 4 2 1 E1 Cross Connect to SDH iSAP5100 offers support for 96 x E1 channels maximum derived from the 16E1 cards and up to 6 installed cards 16x6 96 The STM 1 management card supports only 63 E1 channels Configurations as follows admin iSAP5100 cross e1 cross...

Страница 35: ...e E1 ports VC12 IO ports 4 4 1 Configure Broadcast Source Configurations as follows admin iSAP5100 cross broadcast source add slot 1 port 13 1 broadcast sourse add success admin iSAP5100 cross Set the channel 13 time slot 1 of the 16E1 card in Slot 1 to broadcast source 4 4 2 Configure Broadcast Listener Enter broadcast listener add then the available broadcast listeners will be listed Configurati...

Страница 36: ...e port 15 4 6 SNMP Management 4 6 1 SNMP Setup Configurations as follows admin iSAP5100 config interface snmp admin iSAP5100 snmp snmp snmp snmp server 4 6 2 IP Address Setup Configurations as follows admin iSAP5100 snmp ipconfig 192 168 160 230 255 255 255 0 192 168 160 1 Note IP address format is as follows ipconfig ip address netmask gateway 4 6 3 SNMP Server IP Address Setup Configurations as ...

Страница 37: ...rations as follows admin iSAP5100 snmp write Please wait admin iSAP5100 snmp 4 7 2 Set Time Configurations as follows admin iSAP5100 config settime 2012 12 21 12 12 12 4 7 3 Line Configurations as follows admin iSAP5100 config terminal line 10 4 8 Diagnostics Configuration 4 8 1 E1 Card Loopback Setup Configure E1 local loopback admin iSAP5100 slot 1 16e1 1 loopback llb Configure E1 remote loopbac...

Страница 38: ...1 1 impedance 75ohm 4 8 2 E1 card BERT setup Enable BERT function admin iSAP5100 slot 1 16e1 1 bert enable Insert BERT errors admin iSAP5100 slot 1 16e1 1 bert err ins none 1e 1 1e 3 1e 4 1e 5 Clear BERT admin iSAP5100 slot 1 16e1 1 bert clear Set up BERT pattern admin iSAP5100 slot 1 16e1 1 bert pattern 2e7 1 2e9 1 2e11 1 ...

Страница 39: ...This page is intentionally left blank Date Version Description 2015 7 31 1 3 maps to 0 9e Revise based on v1 3 doc 2017 11 13 1 3 2017 11 received maps to 1 0 Revise RS 232 232 C data rate ...

Страница 40: ......

Отзывы: