![CTC Union iSAP5100 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/ctc-union/isap5100/isap5100_user-manual_2693557033.webp)
Chapter 4. Provisioning
33
When the system is ready, the user will be prompted with login name and password. Enter “
admin
” for both login name
and password.
User Verification
Login:admin
Password:*****
admin@iSAP5100#
Enter the command “configure terminal” to enter the configure mode.
admin@ iSAP5100#
admin@ iSAP5100#
configure terminal
admin@ iSAP5100# (config)
4.1.2
Configure the Clock Source
admin@iSAP5100(config)
system-clock
vc12e1 slot internal
admin@iSAP5100(config)
system-clock slot 1 port 1
admin@iSAP5100(config)
Show the current clock mode configuration:
admin@iSAP5100(config)
show system
========== system dev info ==========
Current time : 04/03/2014 13:45:53
hostname : iSAP5100
syscontact :
syslocation :
Hardware Version : 1.30
Software Version : 1.31
CPLD Version : 1.01
FPGA Version : 1.04
64M bytes DRAM
64M bytes Flash
working clock : 16e1 slot 1 port 3
set clock : 16e1 slot 1 port 1
========== system status info ==========
cpuslot :1
CUPA :working
PM5320_A :normal
PM8316_A :normal
--more-- ('q' for quit, others for continue
4.1.3
E1 Framing Configuration
Enter configuration page of E1 port
admin@iSAP5100(config)
interface slot 1 port 1
Show E1port’s information
admin@iSAP5100(slot-1/16e1-1) show interface
========================= e1status =====================================
port
los lof ais
crc
lomf
works
ledS
1
alarm normal normal normal normal working on
==================e1 config============================================
port
crc
loop
impedance
sensitivity
frame
encode equip
standby
1
disable nloop 120ohm
-20dB
CAS
HDB3 0
1/1