7.9.7
Settings Solar Panel
dT max solar °C
7 (3...30)
Here you can set the temperature difference determining
when charging of solar energy is started.
Type defined as “Coil”. When the solar panels are
this many degrees warmer than the solar coil in the
EcoZenith, the solar panels’ circulation pump (G30)
starts.
Type defined as “Heat exchanger”. When the solar
panels are these many degrees warmer than the lower
tank in the EcoZenith, the solar panels’ circulation
pumps (G30) start.
Solar is always charged primarily in the lower tank. If
enough solar energy and temperature are present, they
are transferred to the upper tank via the heat distribution
pipes.
dT min solar °C
3 (2...20)
When the temperature difference above falls to this set
value, the circulating pump (G30) for the solar panels
stops and the solar energy charge to the lower tank is
terminated.
Min speed pump %
30 (30...100)
Setting for the minimum permissible rpm (in percent) for
the solar panels’ circulation pump.
Max lower tank °C
85 (10...95)
The maximum permitted temperature in the lower
tank. Charging of the lower tank ceases once the set
temperature has been reached.
Max temp. brine °C
18 (1...30)
Setting for maximum permitted brine temperature. This
menu shows if the function "Recharge bedrock" has
been selected in the "Installer/Define/Solar Panels"
menu. Solar charging of the borehole ceases when this
value has been reached.
dT max bedrock °C
60 (3...120)
Setting for start conditions for solar charging of bedrock.
Specifies the temperature difference (solar panels-
bedrock) at which charging begins.
dT min bedrock °C
30 (1...118)
Setting for stop conditions for solar charging of bedrock.
Specifies the temperature difference (solar panels-
bedrock) at which charging stops.
Menu: "Installer/Settings/Solar Panels".
Содержание EcoZenith i555 Pro 1x230V
Страница 2: ......
Страница 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Страница 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Страница 153: ...153 CTC EcoZenith i555 Pro ...
Страница 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Страница 155: ...155 CTC EcoZenith i555 Pro ...
Страница 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Страница 157: ...157 CTC EcoZenith i555 Pro ...
Страница 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Страница 167: ...167 CTC EcoZenith i555 Pro ...
Страница 168: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 72 1 2020 09 22 ...