This is used to set the desired room temperature. Use
the plus (+) and minus (-) buttons to set the desired
temperature (setpoint), which is shown in brackets. The
actual value is shown in front of the brackets.
If heating circuit 3 or "Passive cooling" is installed, the
symbol for room temperature is displayed with the
number "3" at the bottom right of the menu.
If you want to program a temperature reduction, you
can continue to the "Night reduction" or "Holiday"
submenus. Refer to the "Night temperature reduction"
chapter.
You can select "Room sensor: No" in the "Installer/
Defi ne/Heating Circuit" menu. This can be done for
each heating circuit if it is diffi cult to fi nd a position for
the room sensor, if the fl oor heating circuit has separate
room sensors, or if you use a fi replace or open stove.
The alarm LED on the room sensor still functions as
normal.
If you use the fi re or open stove only occasionally, the
fi ring process can affect the room sensor and reduce
the temperature supplied to the radiators. It can then
get cold in other parts of the house. The room sensor
can temporarily be deselected during the fi ring process.
EcoZenith i555 provides heating to the radiators using
the set heating curve. The radiator thermostats reduce
the heating supplied to the section of the house where a
fi re is burning.
When "Holiday reduction" is activated, S will appear
after the brackets. E.g. 24 (25) S.
When "Night reduction" is activated, NS will appear after
the brackets. E.g. 24 (25) NS.
7.2.1
Setting without a room
sensor
If the room sensor is not installed (this can be selected
from the "Installer/Defi ne/Heating Circuit" menu), the
room temperature is adjusted here.
Adjustment if it is too cold indoors
Increase the "Curve inclination/Curve adjustment" value
by a couple of degrees.
Adjustment if it is too warm indoors
Reduce the "Curve inclination/Curve adjustment" value
by a couple of degrees.
i
The radiator thermostats must
always be fully open and operating
correctly when the system is tuned.
i
Wait 24 hours to see if any further
adjustment is required.
The menu shows Heating circuit 1 with a room sensor and
Heating circuit 2 without a room sensor.
If the outdoor temperature is below zero degrees, "Curve
inclination" is displayed (as shown in this example for Heating
circuit 2).
If the outdoor temperature is above zero degrees, "Curve
adjustment" is displayed.
7.3
Heating/Cooling
Содержание EcoZenith i555 Pro 1x230V
Страница 2: ......
Страница 3: ...162 505 72 1 2020 09 22 Installation and Maintenance Manual CTC EcoZenith i555 Pro ...
Страница 152: ...152 CTC EcoZenith i555 Pro 18 Wiring diagram relay card 3x400V ...
Страница 153: ...153 CTC EcoZenith i555 Pro ...
Страница 154: ...154 CTC EcoZenith i555 Pro 19 Wiring diagram relay card 1x230V ...
Страница 155: ...155 CTC EcoZenith i555 Pro ...
Страница 156: ...156 CTC EcoZenith i555 Pro 20 Wiring diagram relay card 3x230V ...
Страница 157: ...157 CTC EcoZenith i555 Pro ...
Страница 158: ...158 CTC EcoZenith i555 Pro 21 Wiring diagram for expansion card ...
Страница 167: ...167 CTC EcoZenith i555 Pro ...
Страница 168: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 72 1 2020 09 22 ...