INSTRUCTION MANUAL Digital Light Engraver
6
Operation and Cleaning
Effective date
30.09.2013
6.2
Operation
6.2.1
Starting the machine
•
Turn the main switch to the "I" position
•
Check the EMERGENCY STOP switch and turn on the machine at the main
switch.
•
Press and hold the start button down for more than one second.
•
Switch on the PC and turn on the monitor, and then wait until it has fully
booted up.
•
Start the main program
by double clicking on this desktop icon
Click on the "R” reference button on the software interface and wait until the
reference run is finished.
The LEDs on the light switch should now be switched on.
Now you will see that the LED status indicator has changed to the active
mode.
LED OFF
LED ON
These displays indicate the
LED’s current power con-
sumption when the LEDs are
in imaging mode
These displays in-
dicate the LED sta-
tus, showing
whether they are
on or off
These displays show
the LED’S current
temperature
CST GmbH
Königsberger Straße 117
47809 Krefeld - Germany
Page 37 of 69
Betriebsanleitung DLE-AF 01.0 engl.docx