CANedge2 Docs, Release FW 01.04.02
Message ID (hex)
items.properties.id
ID of message to transmit in hex. Example: 1FF.
type:
string
Messages Data (hex)
items.properties.data
Data bytes of message to transmit. RTR frames only use the number of bytes do determine the DLC.
Example: 01020304 or 0102030405060708.
type:
string
maxLength:
128
Configuration explained
This section contains additional information and examples.
Period and delay
If multiple transmit messages are defined, it is recommended to spread them in time by using
delay
. It
may not be possible to transmit all messages if they are to be transmitted simultaneously.
0.4.5.5 Heartbeat
This page documents the
heartbeat
configuration
Configuration file fields
This section is autogenerated from the Rule Schema file.
State
state
Enable to periodically transmit heartbeat signal.
type:
integer
default:
0
options:
Disable: [0] Enable: [1]
ID Format
id_format
ID format of heartbeat message.
type:
integer
de-
fault:
1
oneOf:
[{'type': 'integer', 'title': 'Standard (11-bit)', 'enum':
[0]}, {'type': 'integer', 'title': 'Extended (29-bit)', 'enum':
[1]}]
ID (hex)
id
ID of heartbeat message in hex. Example: 1FF.
type:
string
default:
00435353
34