CANedge2 Docs, Release FW 01.04.02
Encryption
Log files can be encrypted on the device. Here, data is streamed through an AES-GCM encryption
scheme prior to persistence on the SD card. Encrypted files have
*.MFE
as file extension.
Note:
It is recommended to use a 40+ character password for proper encryption
Decryption can be done using an implementation of the PBKDF2 algorithm or via CANedge tools (see
the CANedge Intro).
0.4.3 Real-Time-Clock
This page documents the
real-time-clock
configuration
0.4.3.1 Configuration file fields
This section is autogenerated from the Rule Schema file.
Real-Time Clock (RTC) ‘‘ ‘‘
Time synchronization method
properties.sync
Internal real-time-clock synchronization method. The real-time-clock is maintained when the device is
off.
type:
integer
default:
0
options:
Retain current time: [0] Manual update: [1]
Time zone (UTC-12 to UTC+14)
properties.timezone
Adjustment in full hours to the UTC time. Includes daylight savings time if applicable.
type:
integer
default:
0
minimum:
-12
maximum:
14
Adjustment (-129600 to 129600 seconds)
properties.adjustment
Adjustment in seconds to the UTC time. Can be used for fine tuning the internal time.
type:
integer
default:
0
minimum:
-129600
maximum:
129600
0.4.3.2 Configuration explained
This section contains additional information and examples.
The CANedge uses a real-time clock (RTC) with battery backup, which allows it to retain the absolute
date & time when the device is not powered. The RTC enables the CANedge to add absolute timestamps
to recorded messages. The RTC is set to UTC time during production.
Time-zone changes and minor adjustments can be done via the
timezone
and
adjustment
fields.
0.4. Configuration
19
Содержание CANedge1
Страница 1: ...CANedge2 Docs Release FW 01 04 02 Mar 31 2021...
Страница 2: ......
Страница 4: ...ii...