manualshive.com logo in svg
background image

USER GUIDE 

 

 

 

Barometric Pressure / Humidity and 
Temperature Datalogger 

 

Model SD700

 

 

Содержание SD700

Страница 1: ...USER GUIDE Barometric Pressure Humidity and Temperature Datalogger Model SD700 ...

Страница 2: ...d and calibrated and with proper use will provide years of reliable service Please visit the Extech Instruments website www extech com to check for the latest version of this User Guide Extech Instruments is an ISO 9001 certified company Features LCD simultaneously displays Temperature Pressure and Humidity data Datalogger date time stamps and stores readings on an SD card in Excel format for easy...

Страница 3: ...e Display 3 Pressure Display 4 LOG ENTER button 5 SET button 6 AC adaptor socket 7 Sensors 8 TIME button 9 button 10 Reset button 11 RS 232 output 12 SD memory card socket Note Battery Compartment and Tilt Stand are located on the back of the meter 10 11 12 1 2 3 4 5 6 7 8 9 ...

Страница 4: ...ion of this manual to correctly format the card The internal clock must be set to the correct time See the advanced features section of this manual to set the clock The default data structure uses a decimal point as the numeric decimal indicator See the advanced features section to change this to a comma If the SD memory card is not installed EMPTY will appear in the display Displayed error messag...

Страница 5: ...0 000 3 After 30 000 columns a new file HBA01002 xls is created This is repeated every 30 000 columns until HBA01099 XLS At this point a new folder HBA02 is created and the process is repeated HBA10 is the final folder Transferring Data to a PC 1 Remove the memory card from the datalogger and plug it into the SD card slot on the PC 2 Launch Excel and open the data file on the memory card from with...

Страница 6: ...e Enter button to store the value and to step through the various fields 3 SP t Set the sample rate Press the button to select the desired sample rate and press Enter to store the selection The selections are 5 10 30 60 120 300 600 seconds and AUTO In AUTO the data will be stored every time there is a value change of 1 RH OR 1 C 4 bEEP Set the beeper ON or OFF Press the button to select ON or OFF ...

Страница 7: ... Temperature 32 0 to 122 0 F 0 1 F 1 5 F 70 to 90 0 1 4 of rdg 1 RH Relative Humidity 10 to 70 0 1 4 RH 10 0 to 1000 0 hPa 0 1 2 hPa 1000 1 to 1100 0 hPa 0 1 3 hPa 7 5 to 825 0 mmHg 0 1 1 5 mmHg Barometric Pressure 0 29 to 32 48 inHg 0 01 0 1 inHg Note Above specification tests under the environment RF Field Strength less than 3 V M frequency less than 30 MHz only All EU users are legally bound by...

Отзывы: