Crystal Vision
Installation
SW808 User Manual R1.8
33
22/12/2008
2U Indigo GPI Connections
GPI lines 1 to 6 of each module are brought to one of the four remote connectors at the
rear of the frame as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
4
7 (3)
16 (3)
17 (3)
25 (3)
10 (4)
11 (4)
6
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
8
4 (3)
14 (3)
13 (3)
23 (3)
3 (4)
4 (4)
10
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
12
10 (3)
11 (3)
19 (3)
20 (3)
21 (4)
22 (4)
Table shows Pin number (Remote number)
Note:
Remote (rem) 1 and Remote (rem) 3 are 26 way high density ‘D’ type female sockets
and frame ground is pin 2 in each case.
Remote (rem) 2 and Remote (rem) 4 are 26 way high density ‘D’ type male plugs and
frame ground is pin 6 in each case.
1U Indigo GPI connections
GPI lines ‘a’ to ‘f’ of each module connect to one of two rear remote connectors as
follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
4
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
6
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
Table shows Pin number (Remote number)
Note:
Remote 1: 26 way high density D-type socket. Frame ground is pin 2 and +5V @500mA
is pin 1.
Remote 2: 26 way high density D-type plug. Frame ground is pin 6 and +5V @500mA
is pin 15.