Crystal Vision
Using the active control panel
SW808 User Manual R1.8
18
22/12/2008
4.1 Navigating the display
The functions assigned to control panel keys are dependent on the card selected for
control, and the panel mode. The following list illustrates the functions when controlling
the SW808:
•
DEVICE – enters Device menu to select a card or card to control / enter Panel
setup when held down during power up / shows frame status when pressed from
Statesman mode
•
CAL – Enter or leave Statesman mode / enter panel diagnostics mode when held
down during power up
•
Asterisk – enters board rename menu from the Device menu
•
F1 to F4 – soft keys, function assigned within each menu
•
HOME – moves the display to the home menu
•
ENTER – enters selected card home menu from device list
•
Upward arrow – used to move up the menu structure / enter lock panel menu
from the Device menu
•
Rotary control – shaft encoder used to select options or change assigned data
values
Note:
Please refer to the Crystal Vision Control Panel manual for details of the Panel Setup,
Lock Panel and Diagnostic menus.
4.2 Updating the display
The values displayed on an active front panel are only updated when an adjustment is
made and when changing menu level. If changes occur through the use of card edge
controls or through automatic response to GPI signals, the text displayed on the active
front panel will not be updated immediately. If necessary, use the upward arrow to leave
and then re-enter a menu to update the display.