Crystal Vision SW808 Скачать руководство пользователя страница 11

Crystal Vision 

 

The SW808 Controller panel 

SW808 User Manual R1.8 

10  

   22/12/2008 

Multiple routing 

Multiple routing can be performed by creating the required destination-source pairs 
before pressing the TAKE button. The destination buttons will flash to show that they 
have routing waiting for a take. To confirm the routing press the TAKE button and the 
selected routing assignments will all be updated simultaneously.  

This is similar to establishing a single crosspoint except that instead of pressing TAKE 
immediately, further destination-source pairs are created first. 

Note: 

The last destination button pressed does not flash. 

 

Setting up multiple routing: 

 

Press the destination and then the source for each crosspoint assignment 
required in turn – destination buttons flash 

 

Press TAKE to confirm the routing 

Using salvos 

Up to sixteen salvos may be recorded and recalled from the SW808, Statesman, the card 
edge control or by external GPIs. Like macros, salvos do not store board setup data, 
switching mode or reference selection. 

Salvos can be created from the controller panel; by setting up multiple routing and 
pressing SAVE instead of TAKE. All the source and destination buttons will flash to 
indicate that a memory location needs to be selected. The source buttons 1 – 8 represent 
Salvos 1 – 8, and the destination buttons represent Salvos 9 – 16. Select a memory 
location and then press SAVE to confirm. 

Creating a Salvo: 

 

Set up the required routing 

 

Press SAVE – all source and destination buttons flash 

 

Choose a source/destination button for the Salvo - SAVE will flash 

 

Press SAVE to confirm the choice 

 

To recall a Salvo press RECALL, select a memory location and then press RECALL 
again to confirm, or any other button to cancel. 

Recalling a Salvo: 

 

Press RECALL – all source and destination buttons flash 

 

Choose a source/destination button with a previously saved Salvo - RECALL 
will flash 

 

Press RECALL to confirm the choice 

 

Notes: 

Salvos are similar to Macros in that only those crosspoints in the Salvo are changed. All 
other crosspoints will remain as they were before the Salvo was recalled. 

The operation of the panel described here is based on panel software version 4.01. 

 

Содержание SW808

Страница 1: ...n Ltd Lion Technology Park Station Road East Whittlesford Cambridge CB22 4WL England E mail sales crystalvision tv Website www crystalvision tv Tel 44 0 1223 497049 Fax 44 0 1223 497059 SW808 8 x 8 ro...

Страница 2: ...ler operation 9 Changing crosspoint assignments 9 Viewing crosspoint assignments 9 Multiple routing 10 Using salvos 10 3 Statesman 11 3 1 Statesman operation 11 Routing video 12 Selecting the referenc...

Страница 3: ...ory reset 27 6 Installation 28 6 1 Fitting the SW808 module 28 6 2 Setting the reference termination 28 6 3 Rear modules and signal I O 29 6 4 Selecting the reference on the RM20 30 6 5 Enabling the S...

Страница 4: ...os can be created to change a number of crosspoints at once Up to 16 macros or custom routing table assignments may be stored and recalled and up to 16 snapshots of the router table may be captured as...

Страница 5: ...s It can be used in a 2U frame with the RM19 rear connector or in a 1U frame and Desk Top Box by using the RM20 rear connector When used with the four slot RM19 rear connector all eight inputs and eig...

Страница 6: ...using the 422 BUS port at the rear of the panel Standard UTP patch cables may be used with an appropriate adaptor for the Crystal Vision frame remote connector SW808 Controller panel rear view The RJ4...

Страница 7: ...5 patch lead and an in line coupler used to make the required overall cable length Controller panel to frame adaptor and CAT5 patch lead The following tables show how the required panel to frame adapt...

Страница 8: ...10 Pin 7 Pin 16 Pin 14 Pin 11 Pin 4 Pin 17 Pin 13 Pin 19 Pin 5 Pin 25 Pin 23 Pin 20 Desk Top Box Remote 1 RJ45 Slot 1 Slot 2 Pin 8 Pin 8 Pin 7 Pin 7 Pin 9 Pin 16 Pin 4 Pin 18 Pin 17 Pin 5 Pin 26 Pin 2...

Страница 9: ...set destination 1 to source 1 pressing GPI 2 will set destination 1 to source 2 etc The same applies for destination 2 with GPIs 9 16 The GPIs will also give a tally output so that when destination 1...

Страница 10: ...panel lock on and off hold down source 1 button and destination 8 button for approximately 3 seconds Input present Shows which paths have signals The eight LEDs under the source buttons show video in...

Страница 11: ...data switching mode or reference selection Salvos can be created from the controller panel by setting up multiple routing and pressing SAVE instead of TAKE All the source and destination buttons will...

Страница 12: ...l or REMIND remote control panel must be fitted to allow for Statesman control 3 1 Statesman operation The initial view will show an Explorer style view of the connected frames and modules Double clic...

Страница 13: ...ll all change simultaneously when Salvo is clicked Crosspoint changes can be made to occur in the frame or field vertical interval according to SMPTE RP168 or instantaneously A valid SDI or analogue r...

Страница 14: ...ted to the rear of the frame in which the module is used GPI control is limited to recalling Presets or Macros GPI control cannot be used at the same time as the SW808 Controller panel as both use the...

Страница 15: ...lick on Recall to recall setup data from the selected preset GPI Enable should not be checked whilst presets are being created or recalled by this menu to prevent inadvertent GPI operation Enable GPI...

Страница 16: ...hould not be checked whilst macros are being created or recalled by this menu to prevent inadvertent GPI operation Enable GPI controls preset recall when finished if required Macros are similar to Sal...

Страница 17: ...rol panel All eight control panel key LEDs will illuminate The Crystal Vision control panel start up display Control Panel then briefly replaces the version number display If the control panel firmwar...

Страница 18: ...lot number In the example above the card displayed is located in the first frame in slot number 2 When the desired card is selected press the ENTER key to access that card s HOME menu SW808 home menu...

Страница 19: ...n assigned within each menu HOME moves the display to the home menu ENTER enters selected card home menu from device list Upward arrow used to move up the menu structure enter lock panel menu from the...

Страница 20: ...st Presets and Macros press F3 Conf Configure press F4 The following chart shows the available menus The SW808 menu tree Note Function keys and shaft encoder LEDs are illuminated when active Menus or...

Страница 21: ...the required input with the shaft encoder The change is done implicitly when another output is selected or when the Salvo button is pressed If other crosspoint changes are required press the F4 key ag...

Страница 22: ...cro selected by shaft encoder F4 access the Macro Build menu for the Macro selected by the shaft encoder F3 selects input F4 selects output F2 clears any unsaved macro data F1 saves the crosspoint ass...

Страница 23: ...cts name 1 to 16 to change F keys to select the required name sub menu F3 deletes previous input name text F1 and F2 select the character for change Shaft encoder changes character F4 accepts the new...

Страница 24: ...bled The routing table is initialised as IN1 set to OUT1 IN2 set to OUT2 IN3 set to OUT3 and so on to IN8 set to OUT8 Note Reference select is made manually with an RM20 rear connector see Installatio...

Страница 25: ...elects outputs 1 to 8 The 0 or zero positions of the 0 to 15 rotary HEX switches are not assigned Main menu functions Select main functions with the 8 way piano switch bank levers as follows Menu swit...

Страница 26: ...show presence of valid video inputs External reference format is SDI Crosspoint timing is set to Frame GPIs are disabled The Inputs Present LEDs are assigned to inputs as shown in the SW808 front view...

Страница 27: ...uild a salvo table proceed as follows Set the Input and Output Select switches for the first desired connection Set menu lever 4 Set DOWN and UP to store that connection Set the HEX switches for the n...

Страница 28: ...connection Outputs that are set to input 9 are left unchanged when the Macro is recalled Set Menu lever 4 DOWN and UP again to store that connection Set the HEX switches for the next connection Set m...

Страница 29: ...hter module Each SW808 requires two slots To fit an SW808 module line up the module with the RM20 rear connector s two slots or the upper two slots when using the RM19 rear connector Push the two modu...

Страница 30: ...r SW808 Description RM20 6 x SW808s per 2U frame 3 per 1U frame and DTB Only 3 0utputs available 2nd SDI outputs not available GPI lines available at frame remote connectors Frame slots 1 2 3 4 5 6 7...

Страница 31: ...t 6 5 Enabling the SW808 Controller or GPI control The SW808 control lines can be configured for either GPI control or serial control from a SW808 button panel Jumper links determine which control int...

Страница 32: ...0 0 1 1 1 1 0 0 0 0 1 1 1 1 GPI d 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 OPEN 5V GROUND a b c d See table above e Selects Stored Presets Selects stored Macros f Not assigned Not assigned GPI input assignment...

Страница 33: ...12 10 3 11 3 19 3 20 3 21 4 22 4 Slot no a pin b pin c pin d pin e pin f pin 2 7 5 16 5 17 5 25 5 10 6 11 6 4 7 7 16 7 17 7 25 7 10 8 11 8 6 4 5 14 5 13 5 23 5 3 6 4 6 8 4 7 14 7 13 7 23 7 3 8 4 8 10...

Страница 34: ...e rem 1 and Remote rem 3 are 26 way high density D type female sockets and frame ground is pin 2 in each case Remote rem 2 and Remote rem 4 are 26 way high density D type male plugs and frame ground i...

Страница 35: ...nnect to one of two rear remote connectors as follows Slot no a pin b pin c pin d pin e pin f pin 2 7 1 16 1 17 1 25 1 10 2 11 2 Table shows Pin number Remote number Note Remote 1 26 way high density...

Страница 36: ...sent bottom green 5 Input 5 present top green 6 Input 6 present bottom green 7 Input 7 present top green 8 Input 8 present bottom green Inputs Present LED assignments Status LED functions in default m...

Страница 37: ...einsert the card whilst the rack is powered Recalling factory settings If required the card may be reset to factory settings by setting card edge levers 2 and 6 down and simply removing the rack power...

Страница 38: ...t to EN 50083 9 RM20 3 independent ports with 1 reclocked 270Mb s serial digital output per port to EBU Tech 3267 E and SMPTE 259M All outputs are DVB ASI compliant to EN 50083 9 Each will drive 200m...

Страница 39: ...8 22 12 2008 GPI inputs Operation Active connect to ground Inactive high impedance or 3 to 35 volts Input current 500 A SW808 Controller Dimensions 482mm wide 19 inches 44 5mm high 1U 90mm deep Weight...

Отзывы: