Crystal Vision
Hardware installation
SW803 3G User Manual R1.4
8
01/09/2016
1U frame GPI connections
GPI lines ‘a’ to ‘f’ of each card connect to one of two rear remote connectors as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
3
4
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
5
6
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
Table shows pin number (remote number)
Note:
Remote 1: 26-way high-density D-Type female socket. Frame ground is pin 2 and +5V
@500mA is pin 1.
Remote 2: 26-way high-density D-Type male plugs and frame ground is pin 6 and +5V
@500mA is pin 15.
The +5V output is protected by self-resetting thermal fuses, which limit the total output
current available from Remotes 1-2 to approximately 1amp.
Indigo DT desk top box GPI connections
GPI lines ‘a’ to ‘f’ of each card connect to the rear remote connector as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
Table shows pin number (remote number)
Note:
Remote 1: 26-way high-density D-Type female socket. Frame ground is pin 2 and +5V
@500mA is pin 1.
Remote 2: 26-way high-density D-Type male plugs and frame ground is pin 6 and +5V
@500mA is pin 15.
Note. The +5V output is protected by self-resetting thermal fuses, which limit the total output
current available from Remotes 1-2 to approximately 1amp.