GPI control
The SW803 3G may be controlled via GPI lines connected to the rear of the frame in
which the module is used. GPI control is limited to recalling stored presets or macros.
GPI control cannot be used at the same time as the SW808 Controller panel as both use
the same physical control lines. Please refer to the Installation chapter for more
information on using GPIs.
To enable GPI control, select GPI Enable.
Factory settings
The SW803 3G can be either reset to its factory settings or defaults from this menu.
Selecting factory reset will return all customer settable parameters to their default
condition as listed in the following table. If the contents of either the presets or macro
store need to be saved use the Defaults button in place of the Reset button.
Note: Factory reset will erase all saved preset and macro configurations. To preserve contents
of the preset and macro locations use the Defaults command.
Parameter
Default value
Routing
Input 1 to Output 1, Input 2 to Output 2, Input 3 to Output 3
Switch Synchronisation
Field
Reference
Input 1
Presets
Erased (factory reset only)
Macros
Erased (factory reset only)
GPI Enable
Not enabled