All frame connectors are grouped together behind the PSUs at the rear of the frame.
Indigo 2 CoolFlow rear connectors
Connecting mains cables
To connect the Indigo 2 CoolFlow frame to AC mains proceed as follows:
Power the unit by connecting an IEC power cord(s) to the upper and/or lower
IEC connectors depending on the number of installed power supply modules.
Mains cables must have a minimum current rating of 6A and are fitted with an IEC 320
female connector include a protective ground connection and meet relevant local safety
standards.
Tip:
To reduce the risk of electric shock, if two power supply cords are used plug each power
supply cord into separate branch circuits employing separate service grounds.
Note:
The fuse holder is part of the mains inlet. The mains cable must be disconnected before
the fuse can be accessed. Replace the fuse only with one of the same type and rating.
Refer to the Maintenance section of the Trouble shooting guide for more information.